Руководство По Устранению Ошибки для Cisco Cisco Packet Data Gateway (PDG)
Global Configuration Mode Commands
threshold asngw-handoff-denial ▀
Cisco ASR 5000 Series Command Line Interface Reference ▄
OL-22947-02
threshold asngw-handoff-denial
Configures thresholds for hand-off denial for the ASN-GW service.
Product
ASN-GW
Privilege
Security Administrator, Administrator
Syntax
Default: 0
The high threshold number of hand-off denials that must be met or exceeded within the polling interval to
generate an alert or alarm.
The high threshold number of hand-off denials that must be met or exceeded within the polling interval to
generate an alert or alarm.
can be configured to any integer value between 0 and 10000000. A value of 0 disables the
threshold.
Default: 0
The low threshold number of hand-off denials that maintains a previously generated alarm condition. If the
number of hand-off denials falls beneath the low threshold within the polling interval, a clear alarm will be
generated.
The low threshold number of hand-off denials that maintains a previously generated alarm condition. If the
number of hand-off denials falls beneath the low threshold within the polling interval, a clear alarm will be
generated.
can be configured to any integer value between 0 and 10000000. A value of 0 disables the
threshold.
Important:
This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm
model, the system assumes it is identical to the high threshold.
Usage
Use this command to set threshold limits to generate alerts or alarms based on the number of denied hand-off
that occurred during the specified polling interval. Hand-off denial messages are counted for all ASN
Gateways that the system is configured to communicate with.
Alerts or alarms are triggered for hand-off denials based on the following rules:
that occurred during the specified polling interval. Hand-off denial messages are counted for all ASN
Gateways that the system is configured to communicate with.
Alerts or alarms are triggered for hand-off denials based on the following rules:
Enter condition: Actual number of failures ³ High Threshold
Clear condition: Actual number of failures < Low Threshold
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end
of the polling interval.