Руководство По Устранению Ошибки для Cisco Cisco Packet Data Gateway (PDG)

Скачать
Страница из 90
   Engineering Rules 
HNB-GW Engineering Rules  ▀   
Cisco ASR 5000 Series 3G Home NodeB Gateway Administration Guide  ▄  
 
  OL-22991-01 
HNB-GW Engineering Rules 
The following engineering rules apply when the system is configured as an HNB-GW: 
 
 
A maximum of 8 HNB-GW service can be configured on a system which is further limited to a maximum of 256 
services (regardless of type) can be configured per system. 
 
A maximum of 8 HNB-CS network instance can be configured on a system but limited to only one CS network 
instance can be associated with an HNB-GW service. 
 
A maximum of 8 HNB PS network instance can be configured on a system but limited to only one PS network 
instance can be associated with an HNB-GW service. 
 
A maximum of 16 radio PLMN id can be configured in an HNB-GW service. 
 
A maximum of one SeGW IP address can be associated with an HNB-GW service.