Руководство По Устранению Ошибки для Cisco Cisco Nexus 5010 Switch

Скачать
Страница из 3
Nexus 5010/5020 Switches "%NOHMS-2-
NOHMS_DIAG_Error" Message Interpretation
 
Contents
Introduction
Prerequisites
Requirements
Components Used
Problem
Solution
Introduction
This document describes a problem encountered with Nexus 5010/5020 switches caused by a
hardware issue in the Altos ASIC (error message %NOHMS-2-NOHMS_DIAG_ERROR: Module
1: Runtime diag detected major event: Port Failure
), and also provides a solution to the
problem.
Prerequisites
Requirements
Cisco recommends that you have knowledge of the Nexus CLI.
Components Used
The information in this document is based on Cisco Nexus 5010/5020 switches only. It does not
affect Cisco Nexus 5548/5596 switches.
The information in this document was created from the devices in a specific lab environment. All of
the devices used in this document started with a cleared (default) configuration. If your network is
live, make sure that you understand the potential impact of any command.
Problem
Multiple interfaces on Card 2 are down, and you see this alert:
N5020 %$ VDC-1 %$ %NOHMS-2-NOHMS_DIAG_ERROR: Module 1: Runtime diag detected major event
The alert suggests a card failure, but some ports are up. Even though the Nexus 5020 switch is
online, the Fiber Channel (FC) module in Slot 2 is offline. Enter the show module command in
order to view the status of the modules:
Mod Ports  Module-Type                      Model                  Status
--- -----  -------------------------------- ---------------------- ------------
1    40     40x10GE/Supervisor               N5K-C5020P-BF-SUP      active *