Troubleshooting   
▀  Detecting Faulty Hardware 
 
 
▄  ASR 5500 System Administration Guide, StarOS Release 18 
182 
   
Detecting Faulty Hardware 
When power is applied to the chassis, power is sequentially applied to the Management I/O (MIO/UMIO) cards, Data 
Processing Cards (DPC/UDPC/DPC2/UDPC2s), Fabric and Storage Cards (FSCs), and System Status Cards (SSCs). 
Each PFU and card installed in the system incorporates light emitting diodes (LEDs) that indicate its operating status. 
This section describes how to use these status LEDs to verify that all of the installed components are functioning 
properly. 
Important:
  As the system progresses through its boot process, some cards will not exhibit immediate LED 
activity. Allow several minutes to elapse after a reboot is initiates before checking the LEDs on the various cards to 
verify that the boot process has successfully completed. 
Licensing Issues 
The system boot process is governed by StarOS licenses. During the startup process, each card performs a series of 
Power-On Self Tests (POSTs) to ensure that the hardware is operational. These tests also verify that the card meets all 
license requirements to operate in this chassis. 
Refer to Chassis Universal License Requirements in the ASR 5500 Installation Guide for additional information on the 
effect licenses and card types have on the boot process. 
Using the CLI to View Status LEDs 
Status LEDs for all cards can be viewed via the CLI by entering the Exec mode show leds all command. 
[local]host_nameshow leds all 
The following displays a sample of this command’s output. 
Slot 01: Run/Fail: Green       | Active:  Off         | Redundant: Green 
Slot 02: Run/Fail: Green       | Active:  Off         | Redundant: Green 
Slot 03: Run/Fail: Green       | Active:  Off         | Redundant: Green 
Slot 05: Run/Fail: Green       | Active:  Green       | Redundant: Green 
         Master:   Green 
Slot 06: Run/Fail: Green       | Active:  Off         | Redundant: Green 
         Master:   Off 
Slot 08: Run/Fail: Green       | Active:  Off         | Redundant: Green 
Slot 11: Run/Fail: Green       | Active:  Green       | Redundant: Green 
         Status:   Green       | Service: Off  
Slot 12: Run/Fail: Green       | Active:  Green       | Redundant: Green 
         Status:   Green       | Service: Off  
Slot 13: Run/Fail: Green       | Active:  Green       | Redundant: Green 
Slot 14: Run/Fail: Green       | Active:  Green       | Redundant: Green 
Slot 15: Run/Fail: Green       | Active:  Green       | Redundant: Green 
Slot 16: Run/Fail: Green       | Active:  Green       | Redundant: Green 
Slot 17: Run/Fail: Green       | Active:  Green       | Redundant: Green 
The status of the two Power Filter Units (PFUs) can be viewed by entering the Exec mode show power chassis 
command.