для Cisco Cisco Packet Data Gateway (PDG)

Скачать
Страница из 361
  Troubleshooting 
Detecting Faulty Hardware  ▀   
 
ASR 5500 System Administration Guide, StarOS Release 17  ▄  
 
   
181 
Table 21.  DPC/UDPC Run/Fail LED States 
Color
 
Description
 
Troubleshooting
 
Green
 
Card powered up with no 
errors detected.
 
None needed.
 
Blinking 
Green
 
Card is initializing and/or 
loading software.
 
This is normal operation during boot-up.
 
Red
 
Card powered up with 
error(s) detected.
 
Errors were detected during the Power On Self Tests (POSTs). It is likely that the 
errors were logged to the system's command line interface during boot.
 
None
 
Card is not receiving 
power.
 
Verify that the LEDs on the PFUs are blue. If they are not, refer to 
for troubleshooting information.
 
Verify that the power source is supplying ample voltage and current to the chassis.
 
Verify that the card is properly installed and licensed per the instructions in the ASR 
5500 Installation Guide
.
 
If all of the above suggestions have been verified, it is possible that the DPC/UDPC 
is not functional. Please contact your service representative.
 
 
DPC/UDPC Active LED States 
The Active LED on the DDPC/UDPCPC indicates that the software is loaded on the card and that the card is ready for 
operation. When the system first boots up, all installed DPC/UDPCs are booted into standby mode. The system must 
then be configured as to which DPC/UDPCs should serve as redundant components (remain in standby mode) and 
which should function as active components. 
The possible states for this LED are described in the following table. If the LED is not green, use the troubleshooting 
information in the table to diagnose the problem. 
Table 22.  DPC/UDPC Active LED States 
Color
 
Description
 
Troubleshooting
 
Green
 
Card is active.
 
The first time power is applied to the system, all of the DPC/UDPCs should be 
booted into the standby mode. Therefore, this LED should be off.
 
Blinking 
Green
 
Tasks or processes are being 
migrated from an active DPC 
to a standby DPC.
 
Verify that the Redundancy LED on a standby DPC/UDPC is also blinking green. If 
so, there is an issue with the active DPC/UDPC and it is transferring its processes.
 
Refer to Monitoring the System for information on determining the status of the 
DPC/UDPC and system software processes and functionality.
 
None
 
Card is not receiving power. 
OR 
Card is in Standby Mode. 
Verify that the Run/Fail LED is green. If so, the card is receiving power and POST 
results are positive. If it is off, refer to 
 for 
troubleshooting information.
 
Check the state of the Redundancy LED. If it is green, the card is in standby mode. 
This is normal operation for the initial power-up. If needed, refer to the Configuring 
DPC Availability
 section of System Settings for information on making the card 
active.