Troubleshooting   
▀  Detecting Faulty Hardware 
 
 
▄  ASR 5000 System Administration Guide, StarOS Release 18 
218 
   
The possible states for all of the SPIO LEDs are described in the sections that follow. 
SPIO Run/Fail LED States 
The SPIO Run/Fail LED indicates the overall status of the card. This LED should be green for normal operation. 
The possible states for this LED are described in the following table. If the LED is not green, use the troubleshooting 
information in the table to diagnose the problem. 
Table 24.  SPIO Run/Fail LED States 
Color
 
Description
 
Troubleshooting
 
Green
 
Card powered with no 
errors detected.
 
None needed.
 
Red
 
Card powered with 
error(s) detected.
 
Errors were detected during the Power On Self Tests (POSTs). It is likely that the errors 
were logged to the command line interface during the boot process.
 
Refer to Monitoring the System for information on determining the status of system 
hardware components.
 
None
 
Card is not receiving 
power.
 
Verify that the POWER LEDs on the PFUs are green. If they are not, refer to 
for troubleshooting information.
 
Verify that the power source is supplying ample voltage and current to the chassis.
 
Verify that the card is properly installed per the instructions in the ASR 5000 Installation 
Guide
.
 
If all of the above suggestions have been verified, it is possible that the SPIO is not 
functional. Please contact your service representative.
 
 
SPIO Active LED States 
The Active LED on the SPIO indicates that the software is loaded on the card and that the card is ready for operation. 
For the SPIO installed in chassis slot 24, this LED should be green for normal operation. For the SPIO installed in slot 
25, this LED should be off for normal operation. 
The possible states for this LED are described in the following table. If the LED is not green, use the troubleshooting 
information in the table to diagnose the problem.