для Cisco Cisco Packet Data Gateway (PDG)

Скачать
Страница из 453
  Interchassis Session Recovery 
Updating the Operating System  ▀   
 
ASR 5000 System Administration Guide, StarOS Release 18  ▄  
 
   
371 
Both ICSR Chassis 
Log into the CLI of the primary and backup and perform the tasks described below. 
Downloading and Transferring the StarOS Build 
Step 1 
Verify that there is enough free space on the /flash device to accommodate the new operating system image file by 
entering the following Exec mode command: 
[local]host_namedirectory /flash 
Step 2 
Access to the Cisco support site and download facility is username and password controlled. Download the software 
image to a network location or physical device (PCMCIA card) from which it can be uploaded to the /flash device. 
Step 3 
Transfer the new operating system image file to the /flash device on the SMC using one of the following methods: 
Step a 
Copy the file from a network location or local device plugged into the SMC using the copy 
command 
[local]host_namecopy from_url to_url [-noconfirm] 
Step b 
Transfer the file to the /flash device using an FTP client with access to the system. The FTP client 
must be configured to transfer the file using binary mode. 
Step c 
Transfer the file to the /flash device using an SFTP client with access to the system. 
Step 4 
Verify that the image file was successfully transferred to the /flash device by running the Exec mode the following 
command 
[local]host_namedirectory /flash 
Step 5 
Run the show version /flash/image_filename command to verify the build information. For example: 
[local]host_nameshow version /flash/image_filename.bin