для Cisco Cisco Tunnel Terminating Gateway (TTG)

Скачать
Страница из 1630
In Release 8.1, if the active-charging mode is changed from the default (non-optimized) mode to the
Optimized mode, or vice-versa, the system must be rebooted for the change to take effect.
Important
In Release 8.3, this keyword is obsolete. With or without this keyword ACS is always enabled in the
Optimized mode.
Important
Use the require active-charging command to enable ACS in the non-optimized mode. Wherein, ACS
Managers will spawn to support ACS.
Use the require active-charging optimized-mode command to enable ACS in the Optimized mode. Wherein,
ACS is enabled as part of Session Managers.
content-filtering category [ static-and-dynamic ]
Enables the Category-based Content Filtering application with ACS support and creates the necessary Static
Rating Database (SRDB) tasks to utilize the internal database of static/dynamic URLs.
For Dynamic Content Filtering support, the static-and-dynamic keyword must be configured to specify that
the Dynamic Rater Package (model and feature files) must be distributed to rating modules on startup, recovery,
etc. If not configured, by default, the static-only mode is enabled.
Usage Guidelines
Use this command to enable/disable ACS with or without Category-based Content Filtering application on
the chassis.
This command triggers the resource subsystem to switch to ACS-enabled mode and start ACS-related
tasks. This CLI command must be configured before any services are configured, so that the resource
subsystem can appropriately reserve adequate memory for the ACS-related tasks. After configuring this
command, the configuration must be saved and the system rebooted in order to allocate the resources for
ACS upon system startup.
Important
In 8.0 and 8.1 releases, this command must be configured before configuring any services. This is to ensure
that the resource subsystem can appropriately reserve adequate memory for ACS Manager tasks. If this
command is configured after all the Session Manager tasks are already active, the ACS Manager tasks will
not be started even if additional cards are added to the chassis—instead, the chassis must be rebooted.
Examples
In Release 8.0, the following command enables resource subsystem to configure ACS in isolated mode:
require active-charging isoated-mode
In Release 8.1, the following command enables ACS in Optimized mode:
require active-charging optimized-mode
In Release 8.3, the following command enables ACS in Optimized mode:
require active-charging
Command Line Interface Reference, Modes G - H, StarOS Release 19    
337
Global Configuration Mode Commands (L-S)
require active-charging