для Cisco Cisco Packet Data Gateway (PDG)

Скачать
Страница из 424
Switching CDRs   
▀  Switching CDRs from GSS to HDD 
 
 
▄  GTPP Interface Administration and Reference, StarOS Release 16 
422 
   
      gtpp storage-server local file rotation volume mb 40 
      gtpp storage-server local file rotation cdr-count 
<max_CDR_per_file_as_in_gss.cfg> 
      gtpp storage-server local file rotation time-interval 
<max_file_gen_period_as_in_gss.cfg> 
      gtpp dictionary <gtpp_dict_as_in_gss.cfg> 
      gtpp storage-server mode local 
      end 
show configuration | grep gtpp 
Important:
  Note that 
gtpp storage-server mode local
 must be added at the end. 
 
If configuring to a specific GTPP group: 
configure 
   context <billing> 
      gtpp group <gtpp_group> 
      gtpp storage-server local file format <file_format_as_in_gss.cfg> 
      gtpp storage-server local file rotation volume mb 40 
      gtpp storage-server local file rotation cdr-count 
<max_CDR_per_file_as_in_gss.cfg> 
      gtpp storage-server local file rotation time-interval 
<max_file_gen_period_as_in_gss.cfg> 
      gtpp dictionary <gtpp_dict_as_in_gss.cfg> 
      gtpp storage-server mode local 
      end 
show configuration | grep gtpp 
Important:
  Note that 
gtpp storage-server mode local
 must be added at the end. 
Step 3 
Ensure that GSS is still up and running so that already pending requests towards GSS is fully delivered. Without 
flushing out the existing pending requests to GSS, GGSN will not switch to HDD. 
Step 4 
Check and confirm that new CDRs are being written to HDD. 
Step 5 
On the GSS side, you must wait for the time period it takes for the hard file generation, so that remaining CDRs are 
flushed to CDR file.