для Cisco Cisco Packet Data Gateway (PDG)
ECS Changes in Release 17
ECS Enhancements for 17.1 ▀
Release Change Reference, StarOS Release 17 ▄
137
NEMO Prefix Update Trigger
show active-charging rulebase statistics
The following field is newly added to the output of this show command to support NEMO sessions.
UDRs generated for NEMO prefix update
show active-charging udr-format all
The output of this show command will include information on these newly added attributes in the UDR format.
CSCuq30619 - active-charging cli need to be removed from ecs mode
Applicable Products: GGSN, PDSN, P-GW
Feature Changes
Cosmetic Changes to CLI
Previous Behavior: The existing CLI command “
active-charging test-prepaid-auth
” in exec mode has been
removed.
New Behavior: A new CLI command “
debug active-charging test-prepaid-auth
” has been introduced in
exec debug mode. This is a hidden CLI, it is visible only when “
cli test-commands
” is enabled.
Additionally, the CLI “
active-charging service
” has been disabled in exec mode. Now one can enter this CLI
only under the config mode.
CSCuq45238 - Different disconnect reason is required for PCRF unreachable
case
Applicable Products: GGSN, HSGW, P-GW, S-GW
Feature Changes
Value Change for Diagnostics AVP in Rf Record
Previous Behavior: Earlier, only one disconnect reason used to come from session manager to ECS, and there was no
other way to differentiate between IMS Authorization failure and PCRF unreachable scenarios.
other way to differentiate between IMS Authorization failure and PCRF unreachable scenarios.
The Diagnostics AVP used to have the value as PCRF_INITIATED_SESSION_TERMINATION even when PCRF was
unreachable.
unreachable.
New Behavior: Session manager will now send the detailed disconnect reason in Diagnostics field. The Diagnostics
field in Rf record will have separate values when PCRF initiates termination and when PCRF is unreachable.
field in Rf record will have separate values when PCRF initiates termination and when PCRF is unreachable.