Руководство Разработчика для Cisco Cisco Prime Optical 10.3

Скачать
Страница из 688
 
Cisco Prime Optical 10.3 GateWay/CORBA Programmer Reference Guide 
 
 
24
 
Out of Service–Autonomous 
and Management 
(OOS_AUMA)
 
The entity is not operational due to an autonomous event and has been 
administratively removed from service.
 
Table 2-3: Equipment Service State–Secondary (ONS 15310 CL) 
Secondary States (SST)
 
Attribute Value
 
Meaning
 
Unassigned (UAS)
 
The entity is not provisioned in the database.
 
Unequipped (UEQ)
 
The entity has been removed, leaving an empty slot. It may or may not 
be assigned (provisioned).
 
Mismatch of Equipment and 
Attributes (MEA)
 
Incorrect equipment is installed. For example,  
the card plugged in is not compatible with the 
provisioned card or slot.
 
Automatic In-Service (AINS)
 
The entity is in a delay transition (to IS) state. The transition to IS is 
pending the correction of off-normal conditions on the entity.
 
Maintenance (MT)
 
The entity has been manually removed from 
service for maintenance. It is still capable of 
performing its provisioned functions. Traffic is 
still carried.
 
Disabled (DSBLD)
 
The entity has been manually removed from 
service and cannot perform its provisioned 
functions. All of its provisioned services are 
disrupted. Traffic is not carried.
 
Loopback (LPBK)
 
The loopback command is in effect (any loopback 
type).
 
 
2.1.3.3  Topological Links 
All topological links are unidirectional or bidirectional for ONS 15310 CL NEs. 
2.1.3.4  CTX Cards 
The CTX card is an electrical card that consists of 21 digital signal level 1 (DS1) ports and three 
DS3/EC1 ports. Two optical interfaces are supported using SFP technology. OC-3/STM-1 and 
OC-12/STM-4 ports are available. 
2.1.3.5  PTPs 
All PTPs are bidirectional for the ONS 15310 CL. The ports are always in channelized mode. 
PTPs support In Service and Out of Service–Maintenance values for the service state attribute. 
2.1.3.6  CTPs 
All CTPs are in channelized mode for the ONS 15310 CL.  
2.1.3.7  SNCs 
CTX cards perform synchronous transport signal (STS) and VT1.5 switching. The subnetwork 
connection (SNC) name cannot exceed 48 characters. The NE enforces the SNC name character 
limit.