2.1.11.5  Topological Links 
Topological links are unidirectional or bidirectional for ONS 15600 SONET NEs. 
2.1.11.6  PTPs 
All PTPs are bidirectional for the ONS 15600 SONET. These ports are always in channelized mode. 
PTPs support In Service and Out of Service–Maintenance values for the service state attribute. 
2.1.11.7  CTPs 
All CTPs are in channelized mode for the ONS 15600 SONET. Alarm monitoring cannot be turned on or 
off for CTPs. 
2.1.11.8  SNCs 
One ONS 15600 SONET NE supports a maximum of 1536 STS SNCs. 
2.1.11.9  Protection 
The ONS 15600 SONET supports 1+1 protection to create redundancy for optical ports. Protect ports 
must match the working ports. For example, port 1 on an OC-48 card can be protected only by port 1 on 
another OC-48 card.  
2.1.11.10 Autodiscovery 
The ONS 15600 SONET supports automatic discovery of connected elements. Prime Optical can connect 
to one node and retrieve information about all connected nodes. The first time Prime Optical connects to a 
node, it retrieves only the IP address of the connected node; Prime Optical does not retrieve the node 
name. However, Prime Optical must report this element to the users. Because the IP address is unique, 
Prime Optical initializes the name of the newly discovered element with the IP address. An object 
creation event is generated for this managed element with the IP address as the name. Later, Prime 
Optical connects to this element and retrieves all information, including the actual name, and an AVC 
event is generated for the managed element name. The NMS listens to the AVC event for the managed 
element name and invokes managedElementManager::ManagedElementManager_I:: 
getManagedElement. 
2.1.12  ONS 15600 SDH 
See th
 for the ONS 15600 SDH software releases that Prime 
Optical 10.6 supports. 
2.1.12.1  Slots 
The ONS 15600 SDH is a single-shelf NE with 14 slots. The TSC card must occupy slot 5 or slot 10. The 
CXC cards are always 1+1 redundant in slots 6/7 and 8/9. Each CXC card occupies two slots. Slots 1 to 4 
and 11 to 14 are reserved for optical I/O cards. SSXC cards replace CXC cards from release 5.0 of the 
NE. For more information, refer to the Cisco ONS 15600 SDH user documentation. 
2.1.12.2  Topological Links 
Topological links are unidirectional or bidirectional for ONS 15600 SDH NEs. 
2.1.12.3  PTPs 
All PTPs are bidirectional for the ONS 15600 SDH. These ports are always in channelized mode. PTPs 
support In Service and Out of Service–Maintenance values for the service state attribute.