Технические ссылки для Cisco Cisco 1 GHz GainStar Node
78-4038184-01 Rev B
3
Installation Procedure
Installation Procedure
The instructions provided by the manufacturer of the hardline connector contain
important information, but may omit details that help ensure consistently reliable
results.
As a case in point, consider the following instructions and reference drawing that
As a case in point, consider the following instructions and reference drawing that
accompany the Gilbert GRS pin-type connector for CommScope .500 diameter PIII
hardline cable:
Install Back Nut onto cable. Install Main Nut onto cable to check cable trim coring dimensions.... Verify the
connector pin length and, if necessary, trim the connector pin to the appropriate length for the equipment being
used. Install the connector Body into the housing and tighten to housing manufacturer's specification. Slide the
Main Nut onto the prepared end of the cable making certain that the integral sleeve is fully inserted into the cable.
Bring the Main Nut and cable to the Body. Hand tighten Main Nut to Body continually keeping pressure on cable
towards body so that the center conductor will be properly seized. Then, using two wrenches, one wrench to hold
the Body from rotation, continue tightening Main Nut to Body until a firm stop is reached, re-verify that the
integral sleeve is fully inserted into cable. Tighten Back Nut by hand; then, using two wrenches, one of the Main
Nut, complete installation by tightening Back Nut firmly to secure the cable (approximately 35 ft.lbs. [50 Nm];
approximately 50 ft.lbs. [70 Nm] for .840 and larger cable sizes). Secure center conductor in equipment housing
with seizing screw provided by equipment manufacturer 1. Slide heat shrink tubing over connector against port
housing of equipment. Shrink in accordance with manufacturer's recommendation.
Hex A = Body
(Stinger)
1-1/8" Hex
Hex B = Main Nut
(Jam Nut)
1-1/8" Hex
Hex C = Back Nut
(Back Nut)
1" Hex
The following procedures repeat key steps from the instructions quoted above, and
provide additional details and photos to help clarify the best method for carrying
out key steps of the procedure.
Note: Steps quoted from the above procedure are shown in italics below.
Note: Steps quoted from the above procedure are shown in italics below.