Step 2: Install Hardware 
 
78-4041038-01 Rev B 
 
To Connect the Coaxial Pin Connector 
Complete the following steps for each coaxial pin connector to be attached to the 
node housing. 
1  Check the length and condition of the coaxial cable pin. The pin must be straight, 
and the tip must be smooth with no burrs. The pin must measure 1.5 to 1.6 
inches long (3.8 to 4.1 mm) from the tip to the base of the connector threads at the 
o-ring location. Use the cutting length guide on the housing base for reference, as 
shown below. 
 
 
 
Important: The pin must meet the minimum length specified so the tip will 
engage the seizure inside the housing before the connector threads engage the 
housing. The pin must not exceed the maximum length in order to maintain 
proper product performance. 
If necessary, trim the pin using heavy-duty wire cutters, and then file the tip 
smooth. 
Note: Centering the pin length at 1.55 inches (3.95 mm) may make connector 
installation easier. A common approach is to cut the pin 1/16 inch (1.6 mm) 
longer than the cut guide on the housing. 
2  Insert the coaxial connector into the housing at the desired housing port. The tip 
of the pin should engage the spring-loaded seizure. 
Note: It may help to twist the connector back and forth slightly while pressing in 
against the seizure to get the tip of the pin to engage.