Руководство По Установке для Cisco Headend System Release 2.7
![Cisco](https://files.manualsbrain.com/attachments/7380d0050044647c30f5c24bbbf5d0c0b6d9bb84/common/fit/150/50/faa183d287233c52228cfea3dbc2a127fe780f60564fcb0955d9c3d1cd23/brand_logo.png)
Examine Disks and Mirrored Devices
4036631 Rev B
11
6 Is your DNCS platform a Sun Fire V880 or V890?
If yes, type (as root user) luxadm display FCloop and then press Enter to
verify that all slots with disks have a Disk Status of OK.
Example:
verify that all slots with disks have a Disk Status of OK.
Example:
SUNWGS INT FCBPL
Disk Status
Slot Disks
(Node WWN)
0
On (OK)
500000e0108977d0
1
On (OK)
20000004cf2bf3f1
2
On (OK)
500000e010897d30
3
On (OK)
500000e010898090
4
On (OK)
500000e010894d90
5
On (OK)
2000000c5056c543
6
Not Installed
7
Not Installed
8
Not Installed
9
Not Installed
10
Not Installed
11
Not Installed
If no, go to the next procedure in this chapter.
7 Did the output from step 6 reveal a Disk Status of OK for all disks?
If yes, continue with step 8.
If no, call Cisco Services for assistance.