Техническая Спецификация для Cisco Series 9900 RF Signal Manager Active Products (NTSC)

Скачать
Страница из 9
Series 9900 RF Signal Manager Active Products 
 
7
 
 
Specifications 
 
Power Supply Electrical Specifications 
AC Version (Class I & Class II) 
Input Voltage 
85~132 V AC & 180~264 V AC    50/60 Hz   
Transient Noise 
Output voltage returns to ≤1% in <5ms for a 25% dynamic load 
peak and Vo ≤5% 
Over Current Protection 
110 to 155% of rated output current and recovers automatically. 
Over Voltage Protection 
Vo = 0 V DC if Vo exceeds 130% of nominal 
Efficiency 
≥75% (at 230 V AC and full load) 
RFI Suppression 
110 dB 
Output Voltage 
29 V DC ± 1% over rated load 
Output Power 
150 Watts max. 
-48VDC Version 
Input Voltage 
-40 V to –80 V DC 
Input Current 
5A max. @ -48Vdc and full loading 
Efficiency 
80% min. @ -48 V DC and full load 
Over Current Protection 
110 to 155% of rated output current and recovers automatically. 
Over Voltage Protection 
Vo = 0 V DC if Vo exceeds 130% of nominal 
RFI Suppression 
110 dB 
V out 
29 V DC ± 1% over rated load 
Output Power 
150 Watts max. 
 
Equalizers 
Value 
Input Return Loss 
(min.) 
Output Return Loss 
(min.) 
Maximum Insertion 
Loss (with Cablesim) 
Flatness 
50-1000 MHz 
0 dB 
20 dB 
20 dB 
1.0 dB 
± 0.2 dB 
1.5 dB 
20 dB 
20 dB 
1.0 dB 
± 0.2 dB 
3.0 dB 
20 dB 
20 dB 
1.0 dB 
± 0.2 dB 
4.5 dB 
20 dB 
20 dB 
1.0 dB 
± 0.2 dB 
6.0 dB 
20 dB 
20 dB 
1.0 dB 
± 0.2 dB 
7.5 dB 
20 dB 
20 dB 
1.0 dB 
± 0.2 dB 
9.0 dB 
20 dB 
20 dB 
1.0 dB 
± 0.2 dB 
 
High Pass Filters 
450 HPF 
Input/Output Return Loss 
(passband) 
Insertion 
Loss 
Flatness 
450 to 1000 MHz 
-20dB point 
20dB 
1dB 
± 0.4dB 
380 MHz 
550 HPF 
Input/Output Return Loss 
(passband) 
Insertion 
Loss 
Flatness 
550 to 1000 MHz 
-20dB point 
20dB 
1dB 
± 0.4dB 
480 MHz 
650 HPF 
Input/Output Return Loss 
(passband) 
Insertion 
Loss 
Flatness 
650 to 1000 MHz 
-20dB point 
20dB 
1dB 
± 0.4dB 
580 MHz