Белая книга для Cisco Cisco Nexus 2224TP GE Fabric Extender
© 2014 Cisco | IBM. All rights reserved.
Page 24
Create the virtual Fibre Channel interface (Port Channel) on both switches:
N5548-Bottom(config)#
N5548-Bottom(config)#
interface vfc 1032
N5548-Bottom(config-if)#
switchport mode F
N5548-Bottom(config-if)#
bind interface port-channel 201
N5548-Bottom(config-if)#
no shut
N5548-Bottom(config-if)#
N5548-Top(config)#
N5548-Top(config)#
interface vfc 1032
N5548-Top(config-if)#
switchport mode F
N5548-Top(config-if)#
bind interface port-channel 201
N5548-Top(config-if)#
no shut
N5548-Top(config-if)#
4. Create the FCoE VSAN and map it to the VLAN on the switches:
N5548-Bottom(config)#
vlan 200
N5548-Bottom(config-vlan)#
fcoe vsan 200
N5548-Bottom(config-vlan)#
N5548-Top(config)#
vlan 201
N5548-Top(config-vlan)#
fcoe vsan 201
N5548-Top(config-vlan)#
5. Configure the VLANs allowed to transverse the vPC links:
N5548-Bottom(config)#
interface port-channel 20
N5548-Bottom(config-if)#
switchport trunk allowed vlan 1, 200
N5548-Bottom(config-vsan-db)#
N5548-Top(config)#
interface port-channel 20
N5548-Top(config-vsan-db)#
switchport trunk allowed vlan 1, 201
N5548-Top(config-vsan-db)#
6. Bind the entry in the VSAN database on the switches:
N5548-Bottom(config)#
N5548-Bottom(config)#
vsan database
N5548-Bottom(config-vsan-db)#
vsan 200
N5548-Bottom(config-vsan-db)#
vsan 200 interface vfc1032
N5548-Bottom(config-vsan-db)#