Reverse Station Performance 
Units 
 
Notes 
Cross Modulation 
dB 
80 
5, 9 
Composite Second Order (High Side) 
dB 
82 
Unless otherwise noted, specifications reflect typical performance and are referenced to 68°F (20°C). 
Specifications are based upon measurements made in accordance with SCTE/ANSI standards (where 
applicable), using standard frequency assignments. 
Table 4. 
Station Delay Characteristics 
Station Delay Characteristics 
Forward (Chrominance to Luminance Delay) 
Reverse (Group Delay in 1.5 MHz bandwidth) 
Frequency (MHz) 
Delay (ns) 
Frequency (MHz) 
Delay (ns) 
109.25 - 112.83 
13 
5.0 - 6.5  
60 
115.25 - 118.83 
6.5 - 8.0 
22 
121.25 - 124.83 
8.0 - 9.5 
12 
 
 
80.5 - 82.0  
10 
 
 
82.0 - 83.5 
13 
 
 
83.5 - 85.0 
18 
Table 5. 
Station Powering Data 
Station Powering Data 
GainMaker High 
Output HGBT  
I DC 
(Amps) 
 
AC Voltage 
90 
85 
80 
75 
70 
65 
60 
55 
50 
45 
40 
35 
Thermal 
2.21 
AC Current (A) 
0.86 
0.88 
0.88 
0.89 
0.93 
0.98 
1.21 
1.25 
1.37 
1.52 
1.72 
2.01 
Power (W) 
59.6 
59.6 
59.8 
59.1 
59.2 
59.3 
59.0 
59.1 
59.1 
59.5 
59.6 
60.2 
AGC 
2.27 
AC Current (A) 
0.87 
0.90 
0.90 
0.92 
0.95 
1.01 
1.24 
1.26 
1.39 
1.54 
1.75 
2.05 
Power (W) 
60.7 
61.2 
61.2 
60.6 
60.4 
61.2 
60.6 
60.6 
60.7 
60.9 
61.5 
62.0 
AGC with Status 
Mon. & Reverse 
Switch 
2.41 
AC Current (A) 
0.91 
0.94 
0.94 
0.97 
1.01 
1.08 
1.34 
1.38 
1.50 
1.64 
1.90 
2.25 
Power (W) 
64.7 
65.2 
64.9 
65.0 
64.6 
64.2 
64.7 
65.1 
65.0 
65.2 
65.0 
65.9 
Data is based on stations configured for 2-way operation. AC currents specified are based on measurements made 
with typical CATV type ferroresonant AC power supply (quasi-square wave) and GainMaker High Output System 
Amplifier power supply (2.5 A, 24 VDC, pn 4022846). 
DC supply has a user-configurable 30 V, 40 V, or 50 VAC under voltage lockout circuit. Default setting is 30 V 40 V 
or 50 VAC under voltage lockout may be selected by changing the position of the lockout jumper. 
Notes: 
1. 
Reference output tilt is specified as “LINEAR” tilt (as opposed to “cable” tilt). 
2.  Forward Gain and Noise Figure measured with 0 dB input EQ and 1 dB input pad. 
3.  Down tilt, the effect of cable, is represented by a (-). Up tilt, the effect of equalization, is represented by a (+). 
4.  73 CW NTSC channels loaded from 115 to 550 MHz. Digital refers to 550-1002 MHz loading with QAM 
carriers at -6 dB levels relative to analog video carrier levels. 
5.  X-mod (@ 15.75 kHz) specified using 100% synchronous modulation and frequency selective measurement 
device.