Руководство По Установке для Cisco Cisco Prisma II EDR Receiver
3-22
Operation Using the ICIM
78-713378-01 Rev C
Checking Reverse Receiver Alarms Using the ICIM,
Continued
Setting User Alarm Thresholds
User alarms have adjustable thresholds. To change a user alarm threshold from the
factory default, follow the steps below.
1.
At the MODULE menu, press the
STAT
key. The STATUS menu is displayed
on the ICIM.
2.
Press the
SEL
key. The alarm thresholds previously set are displayed. If the
label n/a is displayed, you cannot configure that alarm threshold. Press the
key to highlight the next parameter’s alarm threshold.
3.
When the threshold that you wish to set is highlighted, press the
ENTER
key.
4.
Press the
key or the
key to adjust the alarm threshold.
5.
Press the
ENTER
key to save the changes. Data Saved is displayed.
6.
When finished, press the
MAIN
key to return to the MAIN menu.
Reverse Receiver Alarm Threshold Menus
Some typical alarm threshold menus are shown below.
S T A T U S
- - - - - - - - - -
S h e l f 0
S l o t 6
- - - - - - - - - -
R e v e r s e
D a t a
R e c e i v e r
- - - - - - - - - -
I n P w r 1
M a j H 3 . 2 0 0
M i n H 2 . 0 0 0
M i n L - 4 . 0 0 0
M a j L - 2 0 . 0 0
S T A T U S
- - - - - - - - - -
S h e l f 0
S l o t 6
- - - - - - - - - -
R e v e r s e
D a t a
R e c e i v e r
- - - - - - - - - -
I n P w r 1 M x
M a j H 3 . 2 0 0
M i n H 3 . 2 0 0
M i n L - 1 0 0 . 0
M a j L - 1 0 0 . 0
S T A T U S
- - - - - - - - - -
S h e l f 0
S l o t 6
- - - - - - - - - -
R e v e r s e
D a t a
R e c e i v e r
- - - - - - - - - -
I n P w r 2
M a j H 3 . 2 0 0
M i n H 2 . 0 0 0
M i n L - 4 . 0 0 0
M a j L - 2 0 . 0 0
S T A T U S
- - - - - - - - - -
S h e l f 0
S l o t 6
- - - - - - - - - -
R e v e r s e
D a t a
R e c e i v e r
- - - - - - - - - -
I n P w r 2 M x
M a j H 3 . 2 0 0
M i n H 3 . 2 0 0
M i n L - 1 0 0 . 0
M a j L - 1 0 0 . 0