Руководство По Установке для Cisco Cisco OptoStar II Driver Amplifier

Скачать
Страница из 77
Operating using ICIM LCD, Continued 
Alarm Code List 
The table below lists the alarm information of the OptoStar II 1550 nm DWDM 
forward direct modulation transmitter module. 
Code  Item 
Condition 
LED 
001 
Low Optical 
Output Power 
Output power is 2.2 dB lower 
than standard value (factory 
setting) 
Alarm LED is 
red 
002 
High Optical 
Output Power 
Output power is 1.5 dB higher 
than standard value (factory 
setting) 
Alarm LED is 
red 
003 
High Laser 
Bias Current 
Laser bias current more than 120 
mA 
Alarm LED is 
red 
004 
High Laser 
Temperature 
Laser temperature higher than 
35°C 
Alarm LED is 
red 
005 
Low RF Input 
 
RF input lower than 15 
dBmV/channel (3 channels) 
 
RF input lower than 10 
dBmV/channel 
Alarm LED is 
red 
006 
High Module 
Temperature 
Module temperature higher than 
85°C 
Alarm LED is 
red 
007 
High TEC 
Current 
TEC current higher than 1.5 A 
Alarm LED is 
red 
008 
High RF Input  RF input higher than 20 
dBmV/channel 
Alarm LED is 
red 
009 
High RF Input 
Level into the 
Laser   
RF input signal into the laser 
higher than 50 dBmV/channel 
Alarm LED is 
red 
When the RF input signal into the 
laser is higher than 60 
dBmV/channel, the laser is 
switched OFF automatically. 
When the value is lower than 50 
dBmV/channel, it’s switched ON 
automatically.   
Alarm LED is 
red 
 
 
 
 
 
3-18                                            Operation 