Руководство По Установке для Cisco Cisco OptoStar II Driver Amplifier

Скачать
Страница из 64
Operating using ICIM LCD, Continued 
The RF input level value of channel A is the channel A RF input total power value, 
the scope of its input is 30 to 60 dBmV. In the RF input total power, analog 
channel number, digital channel number and the D-value between analog signal 
and digital signal single channel input level are all known cases, please according 
to the following formula to calculate out the analog signal and digital signal 
single channel input level value. (Note: a is the analog signal single channel input 
level value; b is the digital signal single channel input level value; c is the value of 
digital signal less than analog signal single channel input level; P is the channel A 
RF input total power (dBmV); x is the analog channel number; y is the digital 
channel number.) 
a = P − 10 ∗ log (x +
y
10
c
10
b = a − c 
For example:   
The analog channel number of RF input is x = 78, and the digital channel 
number is y = 75. 
The channel A RF input total power by monitored is P = 34.9 dBmV. 
The value of digital signal less than analog signal single channel input 
level is c = 6.0 dB. 
According to the above formula to calculate out the analog signal single channel 
input level value of channel A is = 15.0 dB, and the digital signal single channel 
input level value is b = 9.0 dB. 
 
Continued on next page 
 
 
3-8 
 
Operation 
OL-29669-02