Справочник Пользователя для LaCie 12big Rack Fibre 131062

Модели
131062
Скачать
Страница из 7
© 2010, LaCie. The LaCie logo is a trademark of LaCie. Other products and brand names mentioned herein  
may be trademarks or registered trademarks of their respective owners. Specifications and appearance are given  
as guidelines and may change without notice.   
www.lacie.com       100113
LaCie 12big Rack Fibre
6TB SATA 
12TB SATA 
7.2TB SAS 
24TB SATA 
12TB SATA 
24TB SATA 
7.2TB SAS 
enterprise 
enterprise 
enterprise 
enterprise 
enterprise 
enterprise 
enterprise 
class drives  class drives 
class drives 
class drives 
class drives 
class drives 
class drives 
 
 
 
 
LaCie 12big 
LaCie 12big 
LaCie 12big 
 
 
 
 
Rack Expansion 
Rack Expansion 
Rack Expansion
131010 
131011 
131031 
131012 
131031 
131032 
131062
2 x 4Gb/s Fibre Channel per controller point-to-point, loop and fabric (switched) topologies
Windows 2003 (IA32, EM64T, IA64); RedHat Linux AS4/EL5 (IA32, EM64T, IA64); SuSE Linux 9/10  
(IA32, EM64T, IA64), Mac OS 10.4 and later
256, 512 LUNs, LUN Masking, >2TB LUNs
up to 5 LaCie 12big Rack Expansions can be connected through miniSAS (SFF-8088) connections
up to 60 SATA drives or 92 SAS drives
60TB
Interface types: SAS (3Gb), SATA-II (3Gb) dedicated bandwidth to each drive 
Max drives per enclosure: 12, 512 logical drives/system, automatic bad sector assignment
Single RAID controller with dual controller option 
RAID modes Supported: Up to 60 SATA or 92 SAS Drives disk arrays with independent RAID modes 0, 1, 5, 6, 
10, and 50 support, selectable stripe sizes (64K, 128K, and 256K) 
RAID protection features: Background initialization, background parity checking, and automatic drive rebuild with 
redundant RAID arrays 
RAID controller cache: 2GB cache per controller (selectable by volume: read, adaptive read-ahead, write 
through, write-back), battery backup
Software: StorView, StorView Path Manager, Snapshot 
Interfaces supported: Ethernet (out-of-band)
Hot-swappable components: disk drives, RAID controllers, power supplies and cooling modules 
Additional features for reliability: StorView Path Manager- Windows host based dynamic multi-path failover 
Snapshot: Up to 24 snapshots per logical drive, and up to 512 snapshots per RAID system
Height: 87.9mm (3.46”) 2 EIA units 
Depth: 550mm (21.65”) 
Width: 443.7mm (17.49”) IEC rack-compliant 
Weight: 32.21kg (71 lbs.) dual controllers with drives
Voltage: 100-240 V AC @ 50/60 Hz single phase 
Input Power: 300W typical 
Input Current: 6.0A (115 VAC), 3.0A (230 VAC)
Temperature: 5º to 40ºC (41º to 104º F) 
Shock: 5g 10ms 1/2 sine 
Humidity: 8% to 80% non-condensing 
Vibration: random 0.21 grms 5-500Hz 
Altitude: 0 to 2,133m (0 to 7,000’) 
Acoustics: <58 dB LpA @20º C
Temperature: 1º to 50ºC (33.8º to 122º F) 
Shock: 30g 10ms 1/2 sine 
Humidity: 8% to 80% non-condensing 
Vibration: random 1.04 grms 2-200Hz 
Altitude: 0 to 12,192m (0 to 40,000’)
Temperature: 1º to 60ºC (33.8º to 140º F) 
Shock: 30g 10ms 1/2 sine 
Humidity: 8% to 80% non-condensing 
Vibration: random 1.04 grms 2-200Hz 
Altitude: 0 to 12,192m (0 to 40,000’)
3-year
Capacity
 
 
 
 
Item Number
External Interface
Supported Operating  
Platforms
Supported Hosts
Expansion
Total Number of Disks
Total Expansion Capacity
Disk Drives 
RAID Controllers 
 
 
 
 
 
System Management 
System Availability 
 
Dimensions 
Electrical 
Environmental: Operating 
 
Environmental:  
Non-Operating 
Environmental: Storage 
 
Warranty
*All tests assume: the performance attained during testing is with a fault-tolerant system and the results gained will be invalid if either a RAID controller or a HDD fails or a rebuild is initiated. If the required bandwidth 
has to be attained with a failure of rebuild in progress, headroom must have been allocated within the initial system design. NLE and standard reads and writes are tested within a mutually exclusive environment. 
Performance may vary from one computer to another.
**All configurations use: 7200 rpm SATA drives / 6-drive RAID 5 arrays / 64K chunk size / WBC set to "Max" / RAC set to "Auto" / 1 LD per array / Sequential Write Optimization set to "High" / Overload Management set to 
"Disabled" / Controller LUN disabled / ATTO HBAs and ATTO multipath driver used / Disable cache writethrough operation when write cache is full / Disable synchronize cache writes to disk / The XSAN metadata drive is 
always on separate storage.
***Video bit rate: for read test purposes it has been defined that SD is uncompressed 8-bit 25FPS (720X576) = 21Mb/s. HD is uncompressed 8-bit 422 25FPS (1920X1080P) = 104Mb/s. As such, if lower resolutions are used more 
streams could potentially be supported. External - for write test purposes it has been defined that HD is uncompressed 10-bit 4:2:2 25FPS (1920X1080P) = 210Mb/s. This will require an external HD source to generate the video.
Recommended for optimal performance in configurations, but not required for purchase.

Hot-swappable.

Hot-swappable if the product is used with dual controller options and multipathing drivers.
1TB= 1000GB. 1GB = 1000MB. 1MB = 1,000,000 Bytes. Total accessible capacity varies depending upon operating environment (typically 10% less).
Capacity and cache memory vary depending upon RAID mode.