Руководство Пользователя для Cisco Cisco Content Security Management Appliance M160

Скачать
Страница из 413
 
9-5
Cisco IronPort AsyncOS 8.0 for Security Management User Guide
 
Chapter 9      Monitoring System Status
  •
Not enabled: The monitoring service is not enabled on the Email Security appliance.
  •
Never connected: The monitoring service is enabled on the Email Security appliance, but no 
connection has been established between the Email Security appliance and the Security 
Management appliance.
  •
Waiting for data: The Email Security appliance has connected to the Security Management 
appliance, which is waiting to receive data.
  •
Connected and transferred data: A connection was established between the Email Security 
appliance and the Security Management appliance, and data were successfully transferred.
  •
File transfer failure: A connection was established between the Email Security appliance and the 
Security Management appliance, but the data transfer failed.
The data transfer status for Web Security appliances can be one of the following values:
  •
Not enabled: The centralized configuration manager is not enabled for the Web Security appliance.
  •
Never connected: The centralized configuration manager is enabled for the Web Security appliance, 
but no connection has been established between the Web Security appliance and the Security 
Management appliance.
  •
Waiting for data: The Web Security appliance has connected to the Security Management 
appliance, which is waiting to receive data.
  •
Connected and transferred data: A connection was established between the Web Security 
appliance and the Security Management appliance, and data were successfully transferred.
  •
Configuration push failure: The Security Management appliance attempted to push a 
configuration file to the Web Security appliance, but the transfer failed.
  •
Configuration push pending: The Security Management appliance is in the process of pushing a 
configuration file to the Web Security appliance.
  •
Configuration push success: The Security Management appliance successfully pushed a 
configuration file to the Web Security appliance.
Data transfer issues can reflect temporary network problems or appliance configuration issues. The 
statuses of “Never connected” and “Waiting for data” are normal, transient statuses when you first add 
a managed appliance to the Security Management appliance. If the status does not eventually change to 
“Connected and transferred data,” then the data transfer status might indicate a configuration issue.
If the “File transfer failure” status appears for an appliance, monitor the appliance to determine if the 
failure was caused by a network issue or by a problem with the appliance configuration. If no network 
issues prevent data transfer and the status does not change to “Connected and transferred data,” then you 
might need to change the appliance configuration to enable data transfer.
System Information
The System Information section of the System Status page provides information about the operating 
system and performance of the Security Management appliance. The Uptime field shows when the 
appliance was last started and how long it has been running. The Version Information area lists the model 
number, the version of AsyncOS, the build and install dates of the operating system, and the serial 
number of the appliance. 
Note
You may need to supply the appliance serial number to assist Cisco IronPort Customer Support with 