Operation Using LCI 
78-748704-01 Rev C 
Check Processor Alarms 
Introduction 
Using LCI, you can check the alarm status of various parameters.  Alarms that you 
can check are listed below. 
 
Alarm  
Alarm Condition  Indication 
Possible Cause 
Summary Status 
Normal or Alarm 
Alarm 
Any alarm in the device. 
External Power 
Status 
Power supply 
indicates a fault 
Alarm 
Check power cord.  Make 
sure power supply is fully 
seated. 
Redundant Mode 
Status 
Indicates Invalid if 
both receivers are 
configured to 
Internal 
redundancy with 
no master. 
Invalid 
Valid=No more than one 
receiver is configured to 
Internal redundancy. 
Invalid=Both receivers are 
configured to Internal 
redundancy with no 
master. 
Framing Status 
The signal cannot 
be framed 
Alarm 
Check fiber connection 
path and bdr transmitter. 
Receiver 1 Status 
Receiver 1 not 
present  
Alarm 
Receiver 1 not present.  
Receiver Clock 1 
Status 
Receiver 1 clock 
operation 
Alarm 
Hardware failure.  Unit 
needs repair. 
Receiver 1 Data 
Status 
Receiver 1 data not 
received 
Alarm 
Check rear line and data 
into receiver. 
Receiver 2 Status 
Receiver 2 not 
present  
Alarm 
Receiver 2 not present.  
Receiver Clock 2 
Status 
Receiver 2 clock 
operation 
Alarm 
Hardware failure.  Unit 
needs repair. 
Receiver 2 Data 
Status 
Receiver 2 data not 
received 
Alarm 
Check rear line and data 
into receiver.