Care and Maintenance 127
4
—— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 
h
Insert the bobbin case so that the S mark on 
the bobbin case aligns with the 
z mark on 
machine as shown below.
• Align the S and z marks.
a
S
mark
b
z
mark
c Bobbin case
• Make sure that the indicated points are 
aligned before installing the bobbin case.
CAUTION
i
Insert the tabs on the needle plate cover into the 
needle plate, and then slide the cover back on.
a Needle plate cover
j
Install the flat bed attachment in its original 
position.
Removing the needle plate
When the thread is tangled and cannot be removed 
by cleaning the race, remove the needle plate.
a
Follow steps 
a
 through 
f
 on page 126.
b
Remove the needle plate by removing the 
screws with the included screwdriver.
c
Remove the tangled thread from the needle 
plate.
d
Return the needle plate to its original position, and 
then tighten the screws with the included screwdriver.
Note
z Align the two screw holes on the needle 
plate with the two holes on the machine.
e
Follow steps 
g
 through 
j
 (page 126-127).
● Never use a bobbin case that is scratched, 
otherwise the upper thread may become 
tangled, the needle may break or sewing 
performance may suffer. For a new bobbin 
case (part code: XE7560-001), contact your 
nearest authorized service center.
● Be sure that the bobbin case is correctly 
installed, otherwise the needle may break.
a