Руководство По Работе для Brother PR-1000

Скачать
Страница из 318
APPENDIX  ————————————————————————————————————————————————————————————————————————————
264
6
Lightly press down the ring, and then use the 
Allen screwdriver (large) to tighten the four 
hexagonal screws on the inside of the ring.
Firmly tighten the screws.
1 Ring
CAUTION
7
Remove the pad inserted in step 
5
.
■ Installing the needle plate spacer
Attach the needle plate spacer to the needle 
plate.
1 Needle plate spacer
■ Preparing the mounting jig
Attach the mounting jig to a stable surface, such 
as a desk.
1
Loosen the thumb screw for the mounting jig 
to open the mounting bracket so that it is 
wider than the thickness of the mounting 
surface.
• The mounting bracket can be mounted 
onto a mounting surface with a thickness 
from 9 mm (3/8 inch) to 38 mm (1-1/2 
inches).
2
Securely clamp the mounting bracket onto 
the mounting surface by tightening the 
thumb screw.
1 Mounting bracket
2 Mounting surface
3 Tighten thumb screw
Make sure that each hexagonal screw is 
firmly tightened. If any screw remains 
loosen, injuries may result.