Справочник Пользователя для Samsung SHR-5082P

Скачать
Страница из 109
 
05 MENU SETUP
menu setup _
31
EVENT RECORD MODE
The detailed list for event mode settings is as 
follows:
Alarm Detection Setup
 
Sensor State 
-  Off: Sensor does not operate. 
-  N.O (Normal Open): Sensor remains open 
all the time. But if it gets closed, an alarm is 
issued. (A Contact)
-  N.C (Normal Close): Sensor remains closed 
all the time. But if it gets open, an alarm is 
issued. (B Contact)
 
Cam
It is used to set a camera that synchronizes 
with the current sensor. The default setting 
follows the sensor number. A sensor can 
synchronize with multiple cameras so multiple 
values can be selected.
You can set a preset for each camera to 
synchronize sensors with cameras. If a sensor 
triggers the corresponding camera, the camera 
can show you the preset location.
 
Alarm-Out
It is used to set the Alarm-Out location when 
any alarm occurs. Currently 5 Alarm Outs are 
available. Select an alarm-out to synchronize 
with the current sensor. But multiple values can 
be selected.
 
Duration
It is used to set the Alarm-Out duration. When 
an alarm occurs, the alarm is output for the 
preset time. You can select any of Off, 3sec, 
5sec, 10sec, 20sec, 30sec, and Continuous.
In case of SHR-5082/5080, only 8 
channels are displayed.
Motion Detection Setup
You can configure the motion detection related 
settings. When the detection area is set, the 
system detects any motion in that area. 
 
M.D State
-  Off: Motion detection does not operate.
-  On: Motion detection is active.
 
Area
This is used to set the motion detection 
area. It is not allowed to set 4 extreme rows 
(Up, Down, Left, Right) because the display 
boundary regions can vary according to the 
monitor specification.
-  Select All: Selects the whole area.
-  Select One: Selects a block unit for each 
time. 
-  Select Quarter: Selects a quarter unit of the 
screen for each time. 
-  Clear All: Clears the whole selection. 
-  Save & Exit: Saves the setting and exits.
-  Exit: Exits without saving.
MENU
Select All
Select One
Select Quarter
Clear All
Save & Exit
Exit
Cancel
OK
Motion Detection Setup
 Cam 
M.D State 
Area  Sensitivity  Alarm-Out  Duration
  1 
Off 
Set 
Very High 
None 
10sec
  2 
Off 
Set 
Very High 
None 
10sec
  3 
Off 
Set 
Very High 
None 
10sec
  4 
Off 
Set 
Very High 
None 
10sec
  5 
Off 
Set 
Very High 
None 
10sec
  6 
Off 
Set 
Very High 
None 
10sec
  7 
Off 
Set 
Very High 
None 
10sec
  8 
Off 
Set 
Very High 
None 
10sec
9-16
Cancel
OK
Alarm Detection Setup
 Sensor  State 
Cam 
Alarm-Out 
Duration
 
Off 
None 
10sec
 
Off
 
None 
10sec
 
Off
 
None 
10sec
 
Off
 
None 
10sec
 
Off
 
None 
10sec
 
Off
 
None 
10sec
 
Off
 
None 
10sec
 
Off
 
None 
10sec
9-16
MENU SETUP
System
Camera
Monitoring
Record Mode
Event Record 
Schedule
Backup
Network
Alarm Detection Setup
Motion Detection Setup
Video Loss Detection Setup
Move/Control
Select
Exit
SHR-5162_Eng.indb   31
2007-8-2   14:47:41