Справочник Пользователя для Samsung SL-C4060FX

Скачать
Страница из 322
Admin Settings | 
181
Security
Allows you to set up the security related settings.
Image Overwrite
You can set the machine to overwrite data stored in the memory. The machine overwrites the 
data with different patterns eliminating the possibilities of recovery. 
   
This feature may not be available depending on models or option kits installed.
 
•  
Automatic Image Overwrite: When a job is completed, there are temporal images left in the 
memory. For security reasons, you can set the machine to automatically overwrite secure 
non-volatile memory. If you want to secure memory space, you can set the machine to 
automatically overwrite secure non-volatile memory.
•  
Manual Image Overwrite: When printing, copying, scanning, and faxing, the machine 
temporarily uses memory space. For security reasons, you can set the machine to manually 
overwrite secure non-volatile memory. If you want to secure memory space, you can manually 
overwrite secure non-volatile memory. You can set the machine to repeat the manual image 
overwrite after the system is rebooted.
•  
Scheduled Image Overwrite: You can set the schedule to manually overwrite the image.
•  
Overwrite Method: You can select the method for overwriting the secure non-volatile 
memory(hard).
-
German VSITR: Select to overwrite the memory 7 times. When overwriting for the 6 times, 
alternate 0x00 and 0xff are used to overwrite the disk, and, in the 7th time, the disk is written 
with 0xAA.
-
DoD 5220.28-M: Select to overwrite the memory 3 times. When overwriting three times, 
patterns 0x35, 0xCA, 0x97 are used to overwrite the disk’s content. This method of 
overwriting the disk is specified by US DoD.
-
Australian ACSI 33: Select to overwrite the memory 5 times. When overwriting 5 times, 
character “C” and its complement alternatively are used to overwrite the disk. After the 2nd 
time, there is a mandatory validation. For the 5th time, random data is used.
-
DoD 5220.22M (ECE): Select to overwrite the memory 3 times. When overwriting three times, 
patterns 0x35, 0xCA, 0x97 are used to overwrite the disk’s content. This method of 
overwriting the disk is specified by US DoD.
-
Custom Overwrite: Select to determine the number of times the memory will be overwritten. 
The hard disk will be overwritten as many times as the number you select.
Authentication
This feature allows you to choose the authentication method for user authentication.
   
You can also use this feature from the SyncThru™ Web Service. Open the Web browser 
from your networked computer and type the IP address of your machine. When 
SyncThru™ Web Service opens, click the 
Security tab > User Access Control. (see "Security 
 
•  
Mode: Select the authentication mode.