Power down the system and disconnect the AC power.
2
Open the server.
3
Move the jumper from the normal operation position, CMOS Clear
by BMC, at pins 2 and 3 to the CMOS Clear Force Erase position,
covering pins 1 and 2 as indicated in the following diagram.
by BMC, at pins 2 and 3 to the CMOS Clear Force Erase position,
covering pins 1 and 2 as indicated in the following diagram.
4
Reconnect the AC power, power up the system.
5
When the system begins beeping, power it down and disconnect
the AC power.
the AC power.
6
Return the CMOS Clear jumper to the CMOS Clear by BMC
location, covering pins 2 and 3.
location, covering pins 2 and 3.
7
Close the server chassis.
8
Reconnect the AC power and power up the system.