Справочник Пользователя для ACR Electronics sat2

Скачать
Страница из 25
 
Y1-03-0148-2 Rev. K 
10 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
NOTE:  Some  countries  may  fine  vessel  owners  for  causing  false  alarms.  The  permanent  breakage  of  the  Activation 
Indicator Plastic Pin is a positive indication of a manual activation. 
 
5.7 
Manual Activation without Deployment 
The beacon can be activated while still in its bracket by placing the thumb switch in the ON position. Activation by this 
method overrides all sensors and turns the beacon “ON.” The caution note above still applies.  
 
5.8 
Deactivation 
If manually activated, r
eturn the thumb switch to the “OFF” position. 
 
If  automatically  activated:  remove  the  beacon  from  the  water.  The  beacon  normally  takes  up  to  12  seconds  to 
deactivate, or place the beacon back into the release bracket. 
 
If the beacon continues to operate after it has been deactivated, remove the four screws holding the unit  together and 
unplug the battery to disable the unit. Return it to a service center for repair. 
 
5.9 
Full Functional Self Test 
 
General Instructions 
Please read all instructions before performing any of the tests. Be prepared to record data from the test.  Beacons may 
be tested in or out of the release bracket. The homing beacon at 121.5 MHz is inhibited during self test. It is strongly 
recommended to perform the full functional self test on the beacon on a monthly basis or prior to a voyage. 
 
The self-test is initiated by momentarily lifting the thumb switch to a vertical position and holding it in this position for at 
least one second (see figure 7). The initiation  of the test is indicated by a beep* and the simultaneous lighting of the 
green and red LEDs. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
TEST 
SUCCESS 
FAIL 
Initial Test Start 
 
 Green, Red LED 
 
Check Data Integrity 
Beep, 
 
 Green, Red 
LED 
Test stopped 
Check 406 MHz Synthesizer 
Beep, 
 
 Green, Red 
LED 
Test stopped 
Check RF Power/Battery 
Beep, 
 
 Green, Red 
LED 
Test stopped 
Successful Test 
 Green LED, Strobe 
 
Figure 7 
Figure 6 
ON position: 
Notice the 
Activation 
Indicator 
Plastic Pin 
has been 
broken off. 
OFF position: 
Note the 
Activation 
Indicator 
Plastic Pin 
*NOTE: The “beeps” are a very high-pitched tone 