Справочник Пользователя для AMX radia dimmer enclosures with breakers
Installation Sheet
RDA-ENC6B and ENC12B
Dimmer Enclosures w/Breakers
The RDA-ENC6B (FG606-13) and RDA-ENC12B (FG606-14) enclosures
provide secure mounting for all AMX Lighting and PROlink controllers, and
lighting modules. The enclosures also contain circuit breakers.
provide secure mounting for all AMX Lighting and PROlink controllers, and
lighting modules. The enclosures also contain circuit breakers.
These enclosures are CE, UL, and C-UL approved. They include circuit
breakers and terminals for multi-phase wiring. They also provide 18
knockouts for 1/2", 3/4", and 1" conduits.
breakers and terminals for multi-phase wiring. They also provide 18
knockouts for 1/2", 3/4", and 1" conduits.
Installation Instructions:
•
For indoor use only.
•
Mount on vertical surface only.
•
Maintain 12" (304.88 mm) minimum clearance above and below the
enclosure.
•
Route class 1 conductors through upper conduit knockouts.
•
Route class 2 conductors through lower conduit knockouts.
•
Use 75°C (167°F) copper conductors only.
•
Install filler plate #28-10500 (RDA-EFP) in all unused openings.
•
Install only UL approved modules (see the UL Number Cross
Reference to AMX Lighting ID table on page 2).
Enclosure Weights:
•
RDA-ENC6B: 16.5 lbs. (7.48 kg)
•
RDA-ENC12B: 17.5 lbs. (7.94 kg)
Dimensions between center lines (from FIG. 2):
RDA-ENC6B:
•
A to B = 16.0" (406.4 mm)
•
B to C = 22.88" (581.2 mm)
RDA-ENC12B:
•
A to B = 16.0" (406.4 mm)
•
B to C = 22.88" (581.2 mm)
Radia enclosures must be mounted on a vertical surface with a minimum of
12" (304.8 mm) clearance above and below the enclosure.
12" (304.8 mm) clearance above and below the enclosure.
Specifications
•
Maximum input wire #1/0 AWG (50mm²)
•
Maximum line input is 140 A (per enclosure )
•
Torque input wire to 44 in-lbs. (5.0 N/m)
•
Wire stripping length: 0.67 inches (17 mm)
•
Input 1 feeds channels 1, 4, 7, and 10
•
Input 2a feeds channels 5 and 11
•
Input 2b feeds channels 2 and 8
•
Input 3 feeds channels 3, 6, 9, and 12
•
Breakers are UL 489 listed 10,000 AIC, 100% Switching Duty,
Hydraulic-Magnetic
The following section cross references the UL ID module numbers and
AMX Lighting module IDs.
AMX Lighting module IDs.
The modules identified are the only ones that can be used in the RDA-
ENC6B and RDA-ENC12B enclosures.
ENC6B and RDA-ENC12B enclosures.
FIG. 1
Top, front, bottom, and side views of the RDA-ENC6B and RDA-ENC12B enclosures
TOP VIEW
SIDE VIEW
RDA-ENC12B
RDA-ENC6B
24.0"
(610 mm)
24.0"
(610 mm)
18.0"
(457.2 mm)
0.75"
(19.05 mm)
6.0"
(152.4 mm)
Top, side, and bottom
views are the same for
both enclosures.
views are the same for
both enclosures.
Sample RDK-ENC12B kit
shown with 2 RDC-PDC
shown with 2 RDC-PDC
RDA-ENC6B Configurations:
- ENC6B/120 20 A Breakers
- ENC6B/240 10 A Breakers
RDA-ENC12B Configurations:
- ENC12B/120 20 A Breakers
- ENC12B/240 10 A Breakers
RDK Configurations:
- RDK-ENC6B with 1 RDC-PDC
- RDK-ENC12B/240 2 RDC-PDC
BOTTOM VIEW
Note:
LINE INPUTS: 140 A MAX PER ENCLOSURE
Use 75° C copper conductors only.
Torque terminals to 44 in-lbs.
Torque terminals to 44 in-lbs.
FIG. 2
Bracket configuration
A to B
B to C
Bottom slot
Top slot
Configuration for
right and left
mounting brackets
for all Radia
enclosures.
right and left
mounting brackets
for all Radia
enclosures.
Maximum mounting
screw size: #12
screw size: #12