Справочник Пользователя для ASUS pike 2008

Скачать
Страница из 60
2-4
Chapter 2: RAID configuration
3.  The following screen appears. Select a channel and press <Enter> to enter 
the setup.
The numbers of the channel depend on the controller.
2.2.1 
RAID 1 volume
The RAID 1 feature supports simultaneous mirrored volumes with two disks.
The RAID 1 feature supports hot swap capability, so when a disk in an RAID 
1 volume fails, you can easily restore the volume, and the swapped disk is 
automatically re-mirrored.
To create a RAID 1 volume:
1.  Turn on the system after installing all SAS hard disk drives.
2.  During POST, press <Ctrl+C> to enter the SAS configuration utility.
LSI Corporation MPT SAS2 BIOS 
MPT2BIOS-7.05.01.00 (2010.02.09) 
Copyright 2000-2010 LSI Corporation.
Press Ctrl-C to start LSI Corp Configuration Utility...
To avoid data loss, do not turn off the system when rebuilding.
Esc = Exit Menu        F1/Shift+1 = Help 
Alt+N = Global Properties   -/+ = Alter Boot Order   Ins/Del = Alter Boot List
LSI Corp Config Utility            v7.05.01.00 (2010.02.09) 
Adapter List
  Global Properties
Adapter             PCI   PCI   PCI   PCI    FW Revision       Status     Boot 
                    BUS   Dev   Fnc   Slot                                Order
 
PIKE 2008
           
04    00    00    07     5.00.00.00-IR     Enabled
    
0