NOTE: 
Use only a UL Listed wall plug-in
power transformer  that has Class 2
outputs and the following characteristics:
Input rating:
99-127 V AC rms 60 llz
150  mA maximum
0utput rating:
27-35 V DC at 200 mA
14-18 V DC at 200 mA
The power transformer 
supplied 
with the
ConntecT/R has these characteristics.
Step 3 — Test the equipment.
After the SPIRIT Attendant ConnecT/R is
Installed, test the SPIRIT Attendant by placing a
call to be answered by the SPIRIT Attendant.
NOTE: If the caller requests the  SPIRIT
Attendant to transfer a call to an extension
number that is between the valid pro-
gramed lowest and highest extension but
there is no station set plugged into that
station port, the caller will be placed on
hold and the SPIRIT Attendant will not bc
able to retrieve the call. To help prevent
this from occuring, careful attention
should be given to setting the lowest/
highest extension numbers and try to avoid
skipping over extension numbers while
assigning them.