Post-Installation Checks
3-5
a
Check that the power supply is plugged into the 
device using a power outlet that is known to be 
working or that the RPS is powered.
b
Check that the main power supply switch on the 
wall is set to the ON position.
c
Check and, if necessary, change the fuse on the 
Switch or plug. See the user guide that accompa-
nies your Switch device for details about fuses.
d
Replace the power cable with a cable known to be 
working.
e
Contact 3Com Technical Support.
Checking that the TR-in-FE Module is Installed 
Correctly
Power up the Switch and check that the Downlink 
Status LED on the front of the Switch is lit Green. 
If the MGMT LED is not lit Green, remove and then 
re-install the TR-in-FE module. 
You can confirm that the TR-in-FE Module is installed 
correctly by accessing the local management screens 
or the LCD panel. If the TR-in-FE Module is installed 
correctly, the TR-in-FE Configuration option appears 
in the Main Menu. 
If the TR-in-FE Configuration option does not appear, 
It could be that the TR-in-FE Module is still initializing. 
If the TR-in-FE Module is still initializing, the MGMT 
LED flashes GREEN.
Checking the Physical Connections
This section assumes that the TR-in-FE Module is cor-
rectly installed.
Check that the Link Status LED on the TR-in-FE 
Module is lit GREEN. If the LED is not lit, there is a 
problem with the physical connection. Follow the 
troubleshooting information below:
a
Ensure that both devices are powered up, and that 
the ports at both ends of the link are enabled.
b
Ensure that the cable is securely connected to the 
port at both ends of the link.
c
If using fiber, check each end of the cable to 
ensure that each of the fiber connectors is correctly 
connected. If your cable connectors can be 
reversed, you may need to reverse the TX and RX 
cable connectors at one end of the link.
d
If using copper, the TX and RX pairs may need to 
be swapped. This requires changing the jumper 
setting on the module. See “Jumper Settings.”
e
Ensure that the fiber connection is not broken.
Some cable connectors have been designed so that 
they cannot be fitted incorrectly. Never use excessive 
force to connect cables.
f
If you are running full duplex, make certain that 
the Fast Ethernet switch supports this mode. A 
repeater will not support full duplex whereas a 
switch such as the SuperStack 3000 will.
g
Remove any objects obstructing the cable and 
straighten out any kinks in the cable.