Ensure that the CoreBuilder 5000 hub contains either a 
PacketChannel or a SwitchChannel backplane. 
To verify that the hub has one of these backplanes, 
enter the command SHOW HUB. The model number 
displayed in the Hub Type field should end in C 
(SwitchChannel) or P (PacketChannel), and one of these 
backplanes should be listed under Backplane Type.
For example:
show hub
Hub Information:
Hub Type: 6017C-AC
Backplane Information:
Backplane Type
Revision
--------------
--------
Load-Sharing Power Distribution module
0
Enhanced TriChannel Backplane
1
RingChannel Backplane
0
SwitchChannel Backplane
2
If your hub does not have an installed PacketChannel or 
SwitchChannel backplane and you require 
communication among SwitchModules, contact 3Com 
or your 3Com representative to order a backplane 
upgrade kit. 
Use the following table to determine the slot 
restrictions that apply to your hub configuration: 
If you are installing only one SwitchModule, you can 
install it in any slot, including a reserved ATM slot. The 
single SwitchModule acts as a stand-alone switch.
If your hub does not have an installed PacketChannel or 
SwitchChannel backplane, you can install only one 
SwitchModule per hub.
Backplane Type
 Hub Type
Installation Guideline
PacketChannel
17-Slot
Install SwitchModules in any 
slot.
10-Slot
7-Slot
SwitchChannel 
(PacketChannel 
plus ATM 
Cell-Switching)
17-Slot
Slots 9, 10, 11, and 12 are 
reserved for the 
CoreBuilder
®
5000 ATM 
Switch/Control Point Module 
(Model Number 3C96416SW).
10-Slot
Slots 9 and 10 are reserved for 
the CoreBuilder 5000 ATM 
Switch/Control Point Module 
(Model Number 3C96416SW).
3.3
Software Prerequisites
Before you install a new SwitchModule:
Determine the DMM module’s software version status. 
Enter the SHOW MODULE ALL command. 
show module all
The following display appears:
Slot
Module
Version
Network
General Info
----- -------
-------
-------- -------------
10.01 6100D-MGT
v1.00
ETHERNET_1
11.01 6000M-RCTL
v1.15
N/A
Active
Ctrl Module
12.01 6000M-ARCTL
v1.15
N/A
Stndby Ctrl
Module
12.02 6000M-AMGT
v6.00
N/A
Master Mgmt
Module
Look in the Version column to get the DMM software 
version. The new SwitchModule functions incorrectly if 
the DMM software version is wrong.
As shown in the previous display example, the 
Advanced DMM/Controller (Model 
Number 6000M-CMGT) appears as two modules in the 
same slot (Model Numbers 6000M-ARCTL and 
6000M-AMGT). The DMM operational code version is 
displayed in the Version field of the -AMGT module.
4.0
Crucial Download Procedure
Review the following procedures before you attempt to 
download software to any SwitchModule in your hub. 
You must use the following procedures if you have 
66xx family SwitchModules installed in your hub.
4.1
Download Procedure for SwitchModules 
Earlier than Version v2.02 and DMMs 
Earlier than Version v5.00 
Use the following procedure for all SwitchModules in your 
hub that are earlier than Version v2.02, and DMMs that 
are earlier than Version v5.00. 
CAUTION: All bridge port communication ceases if 
you use an incorrect download procedure to 
upgrade your SwitchModule and Distributed 
Management Module (DMM) and Advanced DMM 
(A/DMM) software. If you use an IP relay for 
connectivity to download code to the DMM, that 