Troubleshooting
should then hear, after pulling towards you the roll, a ‘clack’ movement showing that the axis 
has rotated clockwise.
To check the electromechanical break, from diagnostic menu, run the test (7.1). 
2.
Lower Axis 
Open the pinch wheel of the PH cleaning roller 
Advance material in order to create a loop under the PH cleaning roller as shown under 
Then pass your hand behind the PH cleaning roller, and rotate the lower belt -> it should rotate 
the lower axis and collect the material. Still rotating the belt: it should reach a point that the 
belt can still rotate (with a higher force) and the used material axis no longer rotates as there is 
no more loose material (there should not be enough force to make the new material rotate, 
which is normal. Here are 2 examples.