Справочник Пользователя для HP proliant ml350
System Unit – Rack
System Unit – Rack
System Unit – Rack
System Unit – Rack
Dimensions
Dimensions
Dimensions
Dimensions (HxWxD)
8.61 x19 x 24 in (21.87 x48.26 x 60.96 cm)
Weight
Weight
Weight
Weight(approximate)
60 lb (27.24 kg) (without hard drives)
Input Requirements
Input Requirements
Input Requirements
Input Requirements
(per power supply)
(per power supply)
Range Line Voltage
100 to 120 VAC/200 to 240 VAC
Rated Input Frequency
50 Hz to 60 Hz
Input Power
538W @ 110 VAC
Rated Input Current
7.4A/3.7A
Line Frequency
Line Frequency
Line Frequency
Line Frequency
50 to 60 Hz
BTU Rating
BTU Rating
BTU Rating
BTU Rating
1, 839 BTU/hr
SCSI Connectors
SCSI Connectors
SCSI Connectors
SCSI Connectors
Two internal HD68 connectors
(Support for either two internal, two external, or a mix of internal/external is available. This
is achieved using an internal to external SCSI cable option kit (PN 159547-B22) and either
of the two SCSI knockouts.)
is achieved using an internal to external SCSI cable option kit (PN 159547-B22) and either
of the two SCSI knockouts.)
Power Supply Output
Power Supply Output
Power Supply Output
Power Supply Output
Power
Power
Power
Power
Power
(per power supply)
(per power supply)
Rated Steady-State Power
500W
Temperature Range
Temperature Range
Temperature Range
Temperature Range
Operating
50° to 95° F (10° to 35° C)
(No direct sustaining sunlight)
(No direct sustaining sunlight)
Storage (up to one year)
-40° to 158° F (-40° to 70° C)
Maximum Wet Bulb
Maximum Wet Bulb
Maximum Wet Bulb
Maximum Wet Bulb
Temperature
Temperature
Temperature
Temperature
Temperature
82.4° F (28° C)
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
(non-condensing)
Operating
10% to 90%
Non-operating
5% to 90%
Acoustic Noise
Acoustic Noise
Acoustic Noise
Acoustic Noise
Idle
(Fixed Disk Drives Spinning)
(Fixed Disk Drives Spinning)
L
L
L
L WAd (BELS)
6.0
L
L
L
L pAm (dBA)
46.3
Operating
(Random Seeks to Fixed Disks)
(Random Seeks to Fixed Disks)
L
L
L
L WAd (BELS)
6.0
L
L
L
L pAm (dBA)
46.5
1.44-MB Diskette Drive
1.44-MB Diskette Drive
1.44-MB Diskette Drive
1.44-MB Diskette Drive
LED Indicators
LED Indicators
LED Indicators
LED Indicators
(front panel)
(front panel)
Green
Read/Write Capacity per
Read/Write Capacity per
Read/Write Capacity per
Read/Write Capacity per
Diskette
Diskette
Diskette
Diskette
Diskette (high/low density)
1.44 MB/720 KB
Drive Supported
Drive Supported
Drive Supported
Drive Supported
One
Drive Height
Drive Height
Drive Height
Drive Height
One-third
Drive Rotation
Drive Rotation
Drive Rotation
Drive Rotation
300 rpm
Transfer Rate
Transfer Rate
Transfer Rate
Transfer Rate
(high/low)
(high/low)
500 K/250 K bits/s
Bytes/Sector
Bytes/Sector
Bytes/Sector
Bytes/Sector
512
Sectors/Track
Sectors/Track
Sectors/Track
Sectors/Track (high/low)
18/9
Tracks/Side
Tracks/Side
Tracks/Side
Tracks/Side (high/low)
80/80
Access Times
Access Times
Access Times
Access Times
Track-to-Track (high/low)
3/6 ms
Average (high/low)
169/94 ms
Settling Time
15 ms
Latency Average
100 ms
Cylinders
Cylinders
Cylinders
Cylinders (high/low)
80/80
Read/Write Heads
Read/Write Heads
Read/Write Heads
Read/Write Heads
Two
QuickSpecs
HP ProLiant ML350 Generation 3
HP ProLiant ML350 Generation 3
HP ProLiant ML350 Generation 3
HP ProLiant ML350 Generation 3
TechSpecs
DA - 11430 Worldwide — Version 38 — February 13, 2004