Menu Contents
C
h
ap
te
r 4
  
 M
e
nu 
S
e
tti
n
gs
ALARM [> ALARM]: Determine whether alarm messages are 
issued or not.
 OFF [>> OFF]: Alarm messages are not issued.
*
ON [>> ON]: Alarm messages are issued.
REF ALARM [> REF ALARM]: Determine whether alarm 
messages related to reference video signal are issued or 
not.
*
OFF [>> OFF]: Alarm messages are not issued.
ON [>> ON]: Alarm messages are issued.
TIME CODE [Time code]: Settings related to the time code 
generator
Description of settings
(For DSR-1600 only)
DF MODE [> DF mode]: Select whether the time counter 
operate in drop frame mode or non-drop frame mode.
Normally select drop frame mode, to keep in 
synchronization with real time. The non-drop frame mode 
is useful for example when using computer graphics, and 
working on a frame count basis.
*
ON (DF) [>> ON (DF)]: Drop frame mode
OFF (NDF) [>> OFF (NDF)]: Non-drop frame mode
TC SELECT [>TC select]: Determine which to display in the 
time counter display, TC or VITC.
VITC [>> VITC]: Display VITC.
*
TC [>> TC]: Display TC.
VITC POS SEL-1 [>VITC pos-1]: Select a line to insert the 
VITC in.
Note
You can insert the VITC signal in two places. To insert it in two 
places, set both this item and also VITC POS SEL-2.
(For DSR-1600)
12 LINE [>> 12 line] to 20 LINE [>> 20 line]: Select any line 
from 12 to 20.
Factory default setting: 16 LINE [>> 16 line]
(For DSR-1600P)
Select a line to insert the VITC in.
9 LINE [>>  9 line] to 22 LINE [>> 22 line]: Select any line 
from 9 to 22.
Factory default setting: 19 LINE [>> 19 line]
VITC POS SEL-2 [>VITC pos-2]: Select a line to insert the 
VITC in.
Note
You can insert the VITC signal in two places. To insert it in two 
places, set both this item and also VITC POS SEL-1.
(For DSR-1600)
12 LINE [>> 12 line] to 20 LINE [>> 20 line]: Select any line 
from 12 to 20.
Factory default setting: 18 LINE [>> 18 line]
(For DSR-1600P)
Select a line to insert the VITC in.
9 LINE [>>  9 line] to 22 LINE [>> 22 line]: Select any line 
from 9 to 22.
Factory default setting: 21 LINE [>> 21 line]
VITC OUTPUT [>VITC out]: Select the time code to be output 
as VITC.
OFF [>> OFF]: Do not output VITC.
TC [>> TC]: Output TC after converting it into VITC.
*
VITC [>> VITC]: Output VITC.
MUTE IN SRCH [>Mute in SR]: Select whether to mute the 
output from the TIME CODE OUT connector in search 
(jog/shuttle) mode.
OFF [>> OFF]: Do not mute.
*
ON [>> ON]: Mute.
TAPE PROTECTION [Tape protct]: Settings related to tape 
and video head protection
Description of settings
FROM STOP [> From STOP]: 
Set the time to switch from 
stop mode to tape protection 
mode.
STOP TIMER [>> STP 
timer]: Set the time to 
switch from stop mode 
to tape protection 
mode.
5 MIN [>>> 5 min] to 0.5 SEC [>>> 0.5 sec]: Select time from 
12 settings ranging from 0.5 second to 5 minutes in steps 
of 0.1 second.
Factory default setting: 1MIN [>>> 1min]
DISPLAY CONTROL [Display]: Settings related to 
indications on the monitor and the unit
Description of settings