2-2  Connector Panel
  Cha
p
te
r 2  
L
o
c
a
tion and
 F
u
nc
tio
n
 of
 P
a
rts
RS232C (serial interface) connector (D-sub 9-pin)
Use this for monitoring and diagnosis of the state of this 
unit from an external computer, using the ISR (Interactive 
Status Reporting) function.
HDV IN (OPTION) connector (6-pin, conforming to 
IEEE1394)
Use an i.LINK cable to connect this unit to an HDV unit 
(HVR-1500, HVR-M25, HVR-M15, HVR-Z1, HVR-A1, 
HDR-FX1, HDR-FX7 or HDR-HC3) recommended by 
Sony. This connector can be used only when an optional 
HKDW-105 i.LINK (HDV) Input Board is installed.
• If video or audio signals from an external device 
connected to the HDV input connector fail to be output, 
disconnect the i.LINK cable and connect it again, 
pushing it straight in. 
• Before connecting or disconnecting an i.LINK cable 
between this unit and a device with a 6-pin i.LINK 
connector, power off the device and disconnect its power 
cord from the electrical outlet. If the i.LINK cable is 
connected or disconnected with the device’s power plug 
still connected, high voltage (8 to 40 V) from the 
device’s i.LINK connector can flow into this unit, 
possibly damaging the unit.
• When connecting this unit to a device with a 6-pin 
i.LINK connector, connect to the 6-pin i.LINK 
connector of the other device first.
Timecode input/output section
TIME CODE IN connector (XLR 3-pin, female)
To record timecode from an external device, input a 
timecode signal from the timecode output connector of the 
external device.
TIME CODE OUT connector (XLR 3-pin, male)
This outputs a timecode according to the operating state of 
the unit, as follows:
• During playback: the playback timecode 
By setting setup menu item 606, you can also output the 
timecode from the internal timecode generator locked to 
the playback timecode.
• During recording: the timecode generated by the 
internal timecode generator or the timecode input to the 
TIME CODE IN connector.
Audio monitor signal output section
MONITOR OUTPUT R (right channel) connector 
(XLR 3-pin, male)
This outputs the audio signals whose output destination 
was set to “R” with the audio monitor signal selection 
buttons in the audio control section. If multiple tracks have 
been set to “R”, the signals of those tracks are mixed for 
output.
MONITOR OUTPUT L (left channel) connector 
(XLR 3-pin, male)
This outputs the audio signals whose output destination 
was set to “L” with the audio monitor signal selection 
buttons in the audio control section. If multiple tracks have 
been set to “L”, the signals of those tracks are mixed for 
output.
Notes
TIME CODE
IN
OUT
2
TIME CODE OUT connector
1
TIME CODE IN connector
MONITOR OUTPUT
R
L
2
MONITOR OUTPUT L 
connector
1
MONITOR OUTPUT R 
connector