Справочник Пользователя для Sony HDW-D1800

Скачать
Страница из 119
88
9-4  Items in the Extended Setup Menu
  
Ch
apt
er 9  Set
up Men
u
s
Menu items in the range 600 to 650, relating to the timecode generator
Item number Item name
Settings
601
VITC POSITION 
SEL-1 (Invalid in 
24PsF or 23.98PsF 
mode)
In 59.94i, 29.97PsF mode
Select a line to insert the VITC in. (For SD output)
12H to 16H to 20H: Select any line from 12 to 20.
Note
You can insert the VITC signal in two lines. To insert it in two lines, set both menu items 
601 and  602.
In 50i, 25PsF mode
Select a line to insert the VITC in. (For SD output)
9H to 19H to 22H: Select any line from 9 to 22.
Note
You can insert the VITC signal in two lines. To insert it in two lines, set both menu items 
601 and 602.
602
VITC POSITION 
SEL-2 (Invalid in 
24PsF or 23.98PsF 
mode)
In 59.94i, 29.97PsF mode
Select a line to insert the VITC in. (For SD output)
12H to 18H to 20H: Select any line from 12 to 20.
Note
You can insert the VITC signal in two lines. To insert it in two lines, set both menu items 
601 and 602.
In 50i, 25PsF mode
Select a line to insert the VITC in. (For SD output)
9H to 21H to 22H: Select any line from 9 to 22.
Note
You can insert the VITC signal in two lines. To insert it in two lines, set both menu items 
601 and 602.
603
ID CODE PRESET
Select whether to set the ID code.
OFF: Do not set.
ON: Set.
To set the ID code:
Select F9 (SET) with this menu item displayed in the menu display, to enter the ID code 
setting mode. Select F1 (PREV) or F2 (NEXT) for digit selection. When all required 
digits have been set correctly, select F9 (SET) again to save the ID code and exit the ID 
code setting mode.
604
ID CODE SW
Select whether to record the ID code, set using menu item 603 in the user bits.
OFF: Record the normal data in the user bits.
ON: Record the ID code in the user bits.
605
TCG REGEN MODE
Select the signals to be regenerated when the timecode generator is in regeneration 
mode (i.e., when F2 (TCG MODE) in function menu page P02: TC is set to “RGN: LTC” 
or “RGN: VITC”).
TC&UB: Both the timecode and user bit signals are regenerated.
TC: Only the timecode signal is regenerated.
UB: Only the user bit signal is regenerated.
606
TC OUTPUT 
SIGNAL IN REGEN 
MODE
Select the signal output from the TIME CODE OUT connector during normal (×1) speed 
playback:
TAPE: During playback, the playback timecode signal is output without regeneration.
REGEN: The playback timecode is output after regeneration.