8-2  Function Menu Item List
  
C
h
ap
te
r 8
  
F
u
nc
tion
 M
e
nu
P03: VID PROC
This is a function menu page for setting items relating to 
video processing.
F10 (TCR)
Select the type of timecode to display in the 
time data display.
LTC: Display LTC.
AUTO: Display VITC when tape speed is 1/
2 or less of normal speed, and LTC 
otherwise.
VITC: Display VITC.
Item
Setting
F1 (VIDEO 
IN)
Select the input video signal.
SDI: HDSDI signal
SG: Test signal from the internal test signal 
generator
 (Normally not displayed. For 
details, see setup menu item 710 
To change to SG, hold down the ALT/
DELETE button, then press the F1 button.
F2 
(REF VID)
Select the reference signal of this unit, 
according to the settings in setup menu 
items 309 and 334, and this unit’s operating 
state.
REF: Use the signal input to a REF. VIDEO 
INPUT connector as the reference 
signal. When recording, input digital 
audio signals and video signals must be 
synchronized with this signal.
INPUT: Use the input video signal as the 
reference signal.
F3 (SYNC 
PHS)
Set the HD output signal sync phase.
With the displayed setting flashing, turn the 
MULTI CONTROL knob to adjust the output 
signal sync phase across the range ±15 µs 
relative to this unit’s input reference signal. 
(The value indication ranges from –128 to 
+127.)
Adjust this item when you want to adjust the 
output signal sync phase precisely to match 
a reference signal, or when connecting this 
unit and other VTRs to a device such as a 
switcher to carry out operations such as 
special effects editing.
Item
Setting
F4 (SYNC 
FIN)
Set the HD output signal sync phase (fine 
adjustment).
With the displayed setting flashing, turn the 
MULTI CONTROL knob to adjust the output 
signal sync phase across the range ±200 
ns relative to this unit’s input reference 
signal. (The value indication ranges from 0 
to 1028.)
Adjust this item when you want to adjust the 
output signal sync phase precisely to match 
a reference signal, or to make further fine 
adjustment when connecting this unit and 
other VTRs to a device such as a switcher 
to carry out operations such as special 
effects editing.
F5 (V.PROC)
Select the control method or setting for the 
internal digital video processor.
LOCAL: Change the settings of the internal 
digital video processor by using this 
function menu.
MENU: Change the settings of the internal 
digital video processor by using F9 
(MENU) in function menu page P01: 
HOME. (For making the settings in the 
setup menus)
Note 
When controlling the unit from the HKDV-
503/900, set this item to “MENU”.
F6 
(VID LEVL)
Set the HD/SD video signal output level 
(–
∞ to +3 dB).
PRESET: Regardless of manually set 
values, the video signal output level is 
set to the standard value.
Manual setting: With the displayed setting 
flashing, turn the MULTI CONTROL 
knob to adjust the video signal output 
level.
F7 
(CHR LEVL)
Set the HD/SD chroma signal output level 
(–
∞ to +3 dB).
PRESET: Regardless of manually set 
values, the chroma signal output level is 
set to the standard value.
Manual setting: With the displayed setting 
flashing, turn the MULTI CONTROL 
knob to adjust the chroma signal output 
level.
F8 (HUE) 
(59.94i mode)/
(CHR  PHAS) 
(50i mode)
Set the hue.
PRESET: Regardless of manually set 
values, the hue is set to the standard 
value.
Manual setting: With the displayed setting 
flashing, turn the MULTI CONTROL 
knob to adjust the value across the 
range ±30º.
Item
Setting