Справочник Пользователя для Panasonic wv-cm146

Скачать
Страница из 22
4
3
2
1
VP CAMERA
PLAY IN
OUT
TIMING SELECT
IN
ALARM
CONTROL
OUT
SPOT MONITOR CONTROL IN
4
3
2
1
RESET
RECOVER
FOCUS
STDBY ALL GND
ON
OFF
REC OUT
OUT
IN
AUDIO
MODE
5
6
7
8
GND
8
7
6
5
CAMERA
CAMERA INPUT
CAMERA POWER
ALARM
CONTROL
OUT
SPOT MONITOR CONTROL IN
4
3
2
1
RESET
RECOVER
STDBY ALL GND
MODE
5
6
7
8
GND
-16-
Intercom
Mater Unit
GND
(+)
ALARM
CONTROL
OUT
SPOT MONITOR CONTROL IN
4
3
2
1
RESET
RECOVER
STDBY ALL GND
MODE
5
6
7
8
GND
Alarm
(
)
(
)
(+)
(+)
Do not connect on AC intercom system.
Two modes can be selected for the Alarm Control Out
works in.
STD BY:
During STAND BY for DISPLAY MODE is select-
ed, this terminal works when SPOT CONTROL IN
received the signal from intercom or alarm sensor/
switch.
ALL MODE:
Regardless of the selected mode for DISPLAY
MODE, this terminal works when SPOT CONTROL IN
received the signal from intercom or alarm sensor/
switch.
The polarities for the alarm and Alarm Control Output of the
monitor should be matched.
The power rate of the alarm should be DC 24 V, max.
100mA.
If the power capacity of the alarm is less than 100 mA, DC
24V, it can be connected to the terminal of Alarm Control
Out directly.
If the power capacity of the alarm is more than 100mA,
DC24V, it can not be connected to terminal directly. In this
case, a relay circuit should be used for the alarm.
NC
NO
C
ALARM
CONTROL
OUT
SPOT MONITOR CONTROL IN
4
3
2
1
RESET
RECOVER
STDBY ALL GND
MODE
5
6
7
8
GND
24V Relay
Diode for
reverse
current
to Alarm
+24V
Auto Reset
This monitor has an auto reset circuit that resets automati-
cally 60 seconds after the intercom or alarm sensor signal
is supplied.
Set AUTO RESET to ON on SET UP MENU.
AUTO RESET activates as follows;
1. In case of using alarm sensors system
The camera that in linked to the alarm signal is select-
ed. After about 60 seconds, the camera picture returns
to sequential switching mode.
2. In case of using intercom system
a. On communication
The camera that is linked to the intercom signal is
selected. The camera picture keeps displayed while
the intercom is on line. The camera picture returns to
sequential switching when the line is disconnected.
b. Calling by the beeper/chime
The camera which is linked to the intercom signal is
selected.
After about 60 seconds, the camera picture returns to
sequential switching mode.
3. In case of using the time lapse VTR
The camera which is linked to the intercom/alarm sig-
nal is selected. After about 60 seconds, the camera
picture returns to sequential switching mode.
The polarities of the intercom system and the Spot Monitor
Control In of the monitor should be matched. Check the
polarities of the intercom system by tester (meter).
Connection with VTR
1. Connect the PLAY IN connector of the monitor to the
VIDEO OUT connector of the time lapse VTR with a
BNC cable.
2. Connect the REC OUT connector of the monitor to the
VIDEO IN connector of the time lapse VTR with a BNC
cable.
3. Connect the TIMING SELECT IN connector of the mon-
itor to the CAMERA SW OUT connector of the time
lapse VTR with an RCA cable.
4. Connect the AUDIO IN connector of the monitor to the
AUDIO OUT connector of the time lapse VTR, and the
AUDIO OUT connector of the monitor to the AUDIO IN
connector of the time lapse VTR with an RCA cable.
Important Notices:
• Set TIMING SELECT to EXT on SET UP MENU and
connect the TIMING SELECT IN connector of the moni-
tor to the CAMERA SW OUT connector of the time
lapse VTR with an RCA cable to record by the time
lapse VTR.
• Set the alarm recording mode of the time lapse VTR to
2H ( 2 hours.)
• When you record in linear mode (L12H, L18H, L24H)
pay attention to the following;
1. Make sure the connections are correct as described
above.
2. During playback, the pictures of other channels or
noise may appear on the display. In this case, play-
back after selecting NORMAL MODE (2H/6H) or TIME
LAPSE MODE of recording.