CHAPTER 5: Troubleshooting your Autoloader
www.gateway.com
70
Running diagnostic tests remotely
You can perform the following diagnostic tests from On-board Remote 
Management:
Important
On-board Remote Management lets you
request all diagnostic tests, but any tests
that require a cartridge to be inserted
times-out unless you manually insert the
cartridge at the appropriate time.
Loader—Self Test
Loader—Health Check
Loader—Picker Test
Loader—Magazine Test
Loader—Inventory Test
Diagnostics using On-board Remote Management
Many tests can be run using On-board Remote Management. 
To perform On-board Remote Management diagnostic tests:
 
1
Open a Web browser and connect to the autoloader (see 
). The On-board Remote Management Main menu 
appears.
2
Click the Diagnostics heading. A login window appears.
3
Type an Administrator user name and a password, then click E
NTER
. The 
Diagnostics submenu appears.
4
Select the test you want to perform from the Diagnostics menu, then click 
Start Test. To halt a test in progress, click Stop Test.
The selected diagnostic test runs. While the test is running, you can view 
the status of the test. To view the status, from the View Diagnostic Test 
Progress, click View Status.
Checking for errors
Errors prevent the autoloader from completing a specific action. When an error 
occurs, two things can happen:
No error message appears, but the autoloader fails to complete the action.
An error message appears on the front panel or in the On-board Remote 
Management screen (see 
When either of these things occur, the system generates a log of the error. You 
can use these error logs to determine the type of error, when it occurred, and 
what parts of the autoloader it affects. The error logs also describe what you 
must do to fix the error, or which parts of the autoloader need to be repaired 
or replaced.
Different types of error logs are generated for the autoloader and the tape drive.