ELECTRICAL ADJUSTMENTS
1.
CAUTION
Use an isolation transformer when performing any
service on this chassis.
Before removing the anode cap, discharge electricity
because it contains high voltage.
When removing a PCB or related component, after
unfastening or changing a wire, be sure to put the wire
back in its original position.
Inferior silicon grease can damage IC's and transistors.
When replacing IC's and transistors, use only specified
silicon grease.
Remove all old silicon before applying new silicon.
(VCR SECTION)
2-1: PG SHIFTER
1.
2.
3.
4.
Connect CH-1 on the oscilloscope to TP1002 and CH-2
to pin 4 of CP1003.
Playback the alignment tape.
Press and hold the Tracking-Auto button on the remote
control more than 2 seconds to set tracking to center.
Press the VOL. DOWN button on the set and the
channel button (3) on the remote control simultaneously
until the indicator REC disappears. If the indicator REC
disappears, adjustment is completed.
(If the above adjustments doesn't work well:)
5.
6.
7.
Press the VOL. DOWN button on the set and the
channel button (3) on the remote control simultaneously
until the indicator REC disappears.
When the REC indicator is blinking, press both VOL.
DOWN button on the set and the channel button (4) on
the remote control simultaneously and adjust the
Tracking +/- button until the arising to the down of Head
Switching Pulse becomes 6.5 
±
 0.5H.
(Refer to Fig. 2-1-A, B)
Press the Tracking Auto button.
6.5H
6.5H
Fig. 2-1-B
CH-2
CH-1
CH-1
CH-2
Fig. 2-1-A
2. BASIC ADJUSTMENTS
2-2: VCO FREERUN
1.
2.
3.
4.
5.
6.
7.
8.
Place the set with Aging Test for more than 10 minutes.
Receive the VHF HIGH.
Disconnect the Antenna while receiving the VHF HIGH
and set to the Noise screen.
Once turn off the Power and turn on the Power again.
Approxi. 3 seconds later, input the Antenna again.
Connect the digital voltmeter between the pin 5 of
CP351
 and the pin 1 (GND) of CP351.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (03) on the remote control to
select "VIF VCO".
Press the VOL. UP/DOWN button on the remote control
until the digital voltmeter is 2.5 
±
 0.5V.
On-Screen Display Adjustment
Unplug the AC plug for more than 5 seconds to set the
clock to the non-setting state. Then, set the volume
level to minimum.
Press the VOL. DOWN button on the set and the
Channel button (9) on the remote control simultaneously
to appear the adjustment mode on the screen as shown
in Fig. 1-1.
1.
2.
Fig. 1-1
Use the Channel UP/DOWN button or Channel button
(0-9) on the remote control to select the options shown
in Fig. 1-2.
Press the MENU button on the remote control to end
the adjustments.
3.
4.
FUNCTION
OSD H
CUT OFF
RF AGC
VIF VCO
H VCO
H PHASE
V SIZE
V SHIFT
R DRIVE
B DRIVE
R BIAS
G BIAS
B BIAS
NO.
00
01
02
03
04
05
06
07
08
09
10
11
12
Fig. 1-2
FUNCTION
BRIGHTNESS
CONTRAST
COLOR
TINT
SHARPNESS
FM LEVEL
LEVEL
SEPARATION 1
SEPARATION 2
TEST MONO
TEST STEREO
X-RAY TEST
NO.
13
14
15
16
17
18
19
20
21
22
23
24
TV
00  OSD        15
BEFORE MAKING ELECTRICAL
ADJUSTMENTS
Read and perform these adjustments when repairing the
circuits or replacing electrical parts or PCB assemblies.