Справочник Пользователя для Toshiba RAV-SM566KRT-TR

Скачать
Страница из 112
No.
‡
Part name
Cross flow
fan
Procedures
<Caution at reassembling>
1) To incorporate the fan motor, remove the
fan motor rubber (at shaft core side),
incorporate the motor into the position in
the following figure, and then install the fan
motor.
Remarks
5.0mm
• Install the cross flow fan so that the right
end of the 1st joint from the right of the
cross flow fan is set keeping 5 mm from
wall of rear plate of the main unit.
• Holding the set screw, install the cross
flow fan so that U-groove of the fan motor
comes to the mounting hole of the set
screw.
• Perform positioning of the fan motor as
follows:
• When assembling the fan motor, the fan
motor must be installed in such a way that
the fan motor leads will be taken out is
positioned at the bottom front.
• After assembling the 2 fixing screws of
the motor band (right) into the main body,
position the fan motor, insert it, and then
secure the motor band (right) using the
2 fixing screws.
FILE NO. SVM-12004
– 
94
 –