Справочник Пользователя для Siemens MC35

Скачать
Страница из 256
AT Command Set
 
 
 
 
 
 
 
MC35_ATC_01_V05.00 
Page 109 of 256 
15.07.2002 
4.33  AT+CPBS  Select phonebook memory storage 
Test command 
AT+CPBS=? 
Response 
+CPBS:
 (list of supported <storage>s) OK 
 
If error is related to ME functionality: 
+CME ERROR: <err> 
 
Parameter 
See write command 
Read command 
AT+CPBS? 
Response 
TA returns currently selected memory: 
+CPBS: <storage>,<used>,<total> OK 
 
If error is related to ME functionality: 
+CME ERROR: <err> 
 
Parameter 
See write command 
Write command 
AT+CPBS= 
<storage> 
Response 
TA selects current phonebook memory storage, which is used by other phone-
book commands. 
OK 
If error is related to ME functionality: 
+CME ERROR: <err> 
 
 
Parameter 
<storage> 
“SM”  SIM phonebook (storage depends on SIM Card) 
 
“FD”  SIM fixdialling phonebook (FD Phonebook storage pos.1-7). 
If the mobile is locked to FD, only the numbers stored to the 
FD memory can be dialled. To edit the FD phonebook PIN 2 
is required. See AT+CLCK  Facility lock, AT^SLCK  Facility 
lock and AT
+CPIN2  Enter PIN2. 
 
“LD”  SIM last-dialling-phonebook (LD Phonebook storage pos.1-
10) (+CPBW not be applicable to this storage) 
 
“MC”  ME missed (unanswered received) calls) (MC Phonebook 
storage pos.1-10) list (+CPBW not applicable to this storage 
 
“RC”  ME received calls list (+CPBW not applicable for this stor-
age) (RC Phonebook storage pos.1-10) 
 
“ON”  SIM (or ME) own numbers (MSISDNs) list  
 
“ME”  ME Phonebook (storage pos.1-50) 
<used>  
Integer type value indicating the number of used locations in se-
lected memory 
<total> 
Integer type value indicating the maximum number of locations al-
lowed in the selected memory 
Reference 
GSM 07.07 
Note 
This command can be used right after power-on to get selected <storage>
Since data need to be loaded from the SIM, values of <used> and <total> might 
not be available for the first 20 seconds.