AT Command Set
 
 
 
 
 
 
 
MC35_ATC_01_V05.00 
Page 154 of 256 
15.07.2002 
 
5.12  AT+CSCA  SMS service centre address 
Test command 
AT+CSCA=? 
Response 
OK 
Read command 
AT+CSCA? 
Response 
+CSCA: <sca>,<tosca> OK 
Parameter 
See write command 
 
Write command 
AT+CSCA=<sca> 
[,<tosca>] 
TA updates the SMSC address, through which mobile originated SMs are 
transmitted. In text mode, setting is used by send and write commands. In PDU 
mode, setting is used by the same commands, but only when the length of the 
SMSC address coded into <pdu> parameter equals zero. 
 
Note:
 This command writes the service centre address to non-volatile memory. 
 
Response
 
OK 
Parameter 
<sca> 
GSM 04.11 RP SC address Address value field in string format; BCD 
numbers (or GSM default alphabet characters) are converted into 
characters; type of address given by
 <tosca> 
Maximum length of address: 20 characters 
<tosca>  Service centre address format GSM 04.11 RP SC address Type-of-
Address octet in integer format (default refer
 <toda>
 
Reference 
GSM 07.05 
Note 
If no parameter is entered after AT+CSCA= the content of <sca> will be deleted.