Справочник Пользователя для Siemens MC35

Скачать
Страница из 256
AT Command Set
 
 
 
 
 
 
 
MC35_ATC_01_V05.00 
Page 196 of 256 
15.07.2002 
 
8.9  AT^SCTM  Set critical operating temperature presentation mode or 
query temperature 
Use this command to monitor the temperature range of the module and the battery. The write com-
mand enables or disables the presentation of URCs to report critical temperature limits. 
CAUTION: During the first 15 seconds after start-up, the module operates in an automatic report 
mode: URCs can be always displayed regardless of the selected mode <n>. 
 
Test command 
AT^SCTM=? 
Response 
^SCTM:
 (list of supported <n>s) OK 
Parameter 
See write command 
 
Read command 
AT^SCTM? 
Response 
TA returns the URC presentation mode and information about the current tem-
perature range of the module. Please note that the Read command does not indi-
cate the temperature range of the battery. The battery temperature can only be 
reported by an Unsolicited Result Code.  
 
^SCTM: <n>, <m> OK 
 
Parameters 
<n>
 
0
  Presentation of URCs is disabled (except for <m> equal to –2 or +2). 
 
1  Presentation of URCs is enabled. 
 
<m> 
-2  Below lowest temperature limit (causes immediate switch-off) 
 
-1  Below low temperature alert limit  
 
 0  Normal operating temperature 
 
 
1  Above upper temperature alert limit 
 
 2  Above uppermost temperature limit (causes immediate switch-off) 
 
Write command 
AT^SCTM=<n> 
Select <n> to enable or disable the presentation of the URCs. Please note that the 
setting will not be stored upon Power Down, i.e. after restart or reset, the default 
<n>=0 will be restored. To benefit from the URCs <n>=1 needs to be selected 
every time you reboot the GSM engine. 
 
Response 
OK 
 
Parameters 
<n>
 
0
 
Suppress URCs (except for <m> equal to –2 or +2) 
 
  1 
Enable presentation of URCs. 
Please see notes below for further details.  
 
 
Unsolicited result code 
URCs will be automatically sent to the TA when the temperature reaches or ex-
ceeds the critical level, or when it is back to normal. 
 
^SCTM_A: <m> 
 
for battery temperature 
 
^SCTM_B: <m> 
 
for module (board) temperature