Справочник Пользователя для Siemens MC35

Скачать
Страница из 256
AT Command Set
 
 
 
 
 
 
 
MC35_ATC_01_V05.00 
Page 33 of 256 
15.07.2002 
 
2.21  ATS3  Write command line termination character 
Read command 
ATS3? 
Response 
<n> OK 
Write command 
ATS3=<n> 
This parameter setting determines the character recognized by TA to terminate 
an incoming command line. 
Response 
OK 
 
Parameter 
<n> 000-013-127 
command line termination character 
 
Reference 
V.25ter 
 
Note 
 
 
2.22  ATS4  Set response formatting character 
Read command 
ATS4? 
 
Response 
<n> OK 
Write command 
ATS4=<n> 
This parameter setting determines the character generated by the TA for result 
code and information text. 
Response 
OK 
 
Parameter 
<n> 000-010-127 
response formatting character. 
Reference 
V.25ter 
 
Note 
 
 
2.23  ATS5  Write command line editing character 
Read command 
ATS5? 
Response 
<n> OK 
Write command 
ATS5=<n> 
This parameter setting determines the character recognized by TA as a request 
to delete the immediately preceding character from the command line. 
Response 
OK 
 
 
Parameter 
<n> 000-008-127 
command line editing character 
 
Reference 
V.25ter 
 
Note