Справочник Пользователя для Siemens MC35

Скачать
Страница из 256
AT Command Set
 
 
 
 
 
 
 
MC35_ATC_01_V05.00 
Page 62 of 256 
15.07.2002 
 
3.27  AT+FVRFC  Vertical resolution format conversion 
Test command 
AT+FVRFC =? 
This command determines the DCE response to a mismatch between the vertical 
resolution negotiated  for the facsimile session and the Phase C data desired by 
the DTE. 
 
Response 
(List of supported mismatch checking modes) OK
 
Parameter 
See write command 
 
Read command 
AT+FVRFC? 
Response 
<vrfc> OK 
Parameter 
See write command 
 
Write command 
AT+FVRFC 
=<vrfc> 
Response 
OK 
Parameter 
<vrfc>
 
disable mismatch checking. 
 
enable mismatch checking, with resolution conversion of 1-D 
data in the DCE, and an implied AT+FK command executed 
on 2-D mismatch detection 
 
Reference 
EIA PN-2388 
Note 
Used for Fax class 2 only 
 
 
The following AT commands are dummy commands. Invoking these commands will not cause ER-
ROR result codes, but these commands have no functionality. 
 
AT+FAA 
Auto Answer mode 
AT+FECM 
Error Correction Mode control 
AT+FLNFC 
Page Length format conversion 
AT+FLPL 
Indicate document available for polling 
AT+FMINSP 
Minimum Phase C speed 
AT+FRBC 
Phase C data receive byte count 
AT+FREL 
Phase C received EOL alignment 
AT+FSPL Enable 
polling 
AT+FTBC 
Phase C data transmit byte count 
AT+FWDFC 
Page width format conversion